{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N1P04DGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N1P04DGN","canonicalUrl":"https://aoctrl.com/schneider/A9N1P04DGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N1P04DGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P04DGN, 1P, 4 A rated, D curve, 10 kA breaking capacity at 240 V AC, clip-on for 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N1P04DGN is a 1-pole miniature circuit breaker from the Acti9 xC60 range, rated 4 A with a D tripping curve. It clips onto a standard 35 mm DIN rail inside a distribution board — the 18 mm width (2 x 9 mm pitches) matches the modular grid of a residential or light commercial panel. The D curve means its magnetic trip operates at 10 to 14 times the rated current (40 to 56 A instantaneous), which is the right characteristic for loads with a high inrush — think small transformers, solenoid valves, or motor starters where a B or C curve would nuisance-trip on startup. For a 4 A device, that inrush tolerance is the main selection criterion. ## Breaking capacity and standards Rated breaking capacity is 10,000 A Icn at 240 V AC, 50/60 Hz, certified to IS/IEC 60898-1. Tropicalisation class 2 per IEC 60068-1 covers damp heat; the 95 % RH at 55 °C rating confirms it holds up in high-humidity environments without internal tracking. ## Termination and wiring The IP20 finger-safe front is standard for enclosed distribution boards.","metaTitle":"Schneider Electric A9N1P04DGN Acti9 xC60 MCB, 4A D Curve, 1P","metaDescription":"Schneider Electric A9N1P04DGN Acti9 xC60 miniature circuit breaker. 4 A rated current, D curve, 1P, 10 kA breaking capacity at 240 V AC. IS/IEC 60898-1. Active production. Sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"4 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N1P04DGN/miniature-circuit-breaker-mcb-acti9-xc60-1p-4a-d-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N1P04DGN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9N1P04DGN?","answer":"10,000 A Icn at 240 V AC, 50/60 Hz, certified to IS/IEC 60898-1."},{"question":"What loads is the D curve on a 4 A MCB meant for?","answer":"The D curve trips magnetically at 10 to 14 times In (40 to 56 A), so it handles high inrush currents from small transformers, solenoid valves, or motor starters without nuisance tripping."},{"question":"Where can I buy the A9N1P04DGN and how is it quoted?","answer":"This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N1P04DGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N1P04DGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}