{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N1P06CIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N1P06CIN","canonicalUrl":"https://aoctrl.com/schneider/A9N1P06CIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N1P06CIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60, A9N1P06CIN, miniature circuit breaker, 1P, 6 A, C-curve, 10 kA Icu at 240 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N1P06CIN is a single-pole Acti9 xC60 miniature circuit breaker rated 6 A with a C-curve trip characteristic. It clips onto a standard 35 mm DIN rail in a distribution board or panel enclosure, occupying 18 mm width (2 x 9 mm pitches). The thermal-magnetic trip unit handles overloads and short-circuits; the C-curve means magnetic tripping occurs at 5 to 10 times In (here 8 x In ±20 % per the spec), so it suits mixed resistive and light inductive loads like general-purpose socket circuits, small lighting groups, and control transformers. Rated 10 kA Icu at 220…240 V AC 50/60 Hz per IS/IEC 60947-2, 15 kA Icu at 12…48 V DC, and 6 kA Icu at 60 V DC. That 10 kA at 240 V is the standard interrupting rating for most residential and light commercial distribution boards in markets following IEC 60947-2. The limitation class is 3, meaning it lets through less fault energy than a Class 1 or 2 device — useful for protecting downstream equipment and reducing arc-flash stress on the panel. Listed as current production (active lifecycle stage). This is a standard catalogue item in the Acti9 range, widely used across IEC markets. No obsolescence notice or last-time-buy window is in effect. ## Installation notes for the panel builder Tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible on the bottom; wire strip length 13 mm. Tightening torque 2 N·m. IP20 finger-safe front, so it's fine inside an enclosed panel but not for exposed or wet locations. The ON/OFF toggle gives local visual indication. Earth-leakage protection requires a separate residual current block (not integrated).","metaTitle":"Schneider Electric A9N1P06CIN Acti9 xC60 MCB, 6 A C-Curve, 1","metaDescription":"Schneider Electric A9N1P06CIN Acti9 xC60 miniature circuit breaker, 6 A rated, C-curve, 10 kA breaking capacity at 240 V AC. IS/IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC DC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"6 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 12...48 V DC 60 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA conforming to IS/IEC 60947-2 - 12...48 V DC 6 kA conforming to IS/IEC 60947-2 - 60 V DC","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N1P06CIN/miniature-circuit-breaker-mcb-acti9-xc60-1p-6a-c-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N1P06CIN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N1P06CIN?","answer":"10 kA Icu at 220…240 V AC 50/60 Hz per IS/IEC 60947-2, 15 kA at 12…48 V DC, and 6 kA at 60 V DC."},{"question":"What standards does the A9N1P06CIN comply with?","answer":"It is certified to IS/IEC 60947-2, with tropicalisation class 2 per IEC 60068-1 and limitation class 3 per IS/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N1P06CIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N1P06CIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}