{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N1P10BGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N1P10BGN","canonicalUrl":"https://aoctrl.com/schneider/A9N1P10BGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N1P10BGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit breaker, 1P, 10 A, B curve, 10 kA Icn at 240 V AC, IS/IEC 60898-1, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N1P10BGN is an Acti9 xC60 miniature circuit breaker — a single-pole thermal-magnetic MCB rated 10 A with a B curve and a breaking capacity of 10000 A Icn at 240 V AC 50/60 Hz, certified to IS/IEC 60898-1. The 10 A rated current (In) sets the continuous load this MCB carries without tripping. The B curve means magnetic tripping occurs at 3 to 5 times In — 30 to 50 A — so it clears short-circuit faults fast but tolerates modest inrush from resistive or lighting loads. For distribution panels in commercial or light industrial buildings on 220...240 V AC networks, this covers most branch-circuit faults. The 18 mm width (2 modules) fits compactly in a multi-way distribution board. IP20 rated — suitable for dry indoor panels only, not washdown or outdoor use.","metaTitle":"Schneider Electric A9N1P10BGN Acti9 xC60 MCB, 10 A B Curve 1","metaDescription":"Schneider Electric A9N1P10BGN Acti9 xC60 miniature circuit breaker, 10 A rated current, B curve, 1 pole, 10 kA breaking capacity at 240 V AC, IS/IEC 60898-1. Sourced to order again","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N1P10BGN/miniature-circuit-breaker-mcb-acti9-xc60-1p-10a-b-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N1P10BGN/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N1P10BGN?","answer":"The A9N1P10BGN is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is A9N1P10BGN's breaking capacity?","answer":"The A9N1P10BGN has a breaking capacity of 10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1."},{"question":"What is the B curve on this MCB?","answer":"The B curve means magnetic tripping occurs at 3 to 5 times the rated current (30 to 50 A for this 10 A unit), providing fast short-circuit protection while allowing for moderate inrush from resistive or lighting loads."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N1P10BGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N1P10BGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}