{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N1P20DIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N1P20DIN","canonicalUrl":"https://aoctrl.com/schneider/A9N1P20DIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N1P20DIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N1P20DIN, 1-pole, 20 A rated, D curve, 10 kA Icu at 240 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N1P20DIN is an Acti9 xC60 miniature circuit-breaker rated 20 A with a D tripping curve, single-pole, designed for distribution applications per IS/IEC 60947-2. The D curve means magnetic trip occurs at 12 x In (240 A) with a ±20 % tolerance, so it handles high inrush loads like motor starters or transformer primaries without nuisance tripping on startup. Breaking capacity is 10 kA Icu at 220…240 V AC 50/60 Hz, 15 kA Icu at 12…48 V DC, and 6 kA Icu at 60 V DC — all conforming to IS/IEC 60947-2. For a 20 A feeder, 10 kA SCCR at 240 V is typical for light industrial panelboards; the DC ratings let it serve control circuits on battery-backed or rectified supplies. The limitation class is 3 per IS/IEC 60947-2, meaning it limits let-through energy enough to protect downstream wiring and loads in most fault scenarios. Clip-on mounting to a standard 35 mm DIN rail, 18 mm width (2 x 9 mm pitches), 85 mm height, 77.5 mm depth — fits a standard 4-module panel space. Tightening torque 2 N·m; strip length 13 mm.","metaTitle":"Schneider Electric A9N1P20DIN Acti9 xC60 MCB, 20 A, D Curve,","metaDescription":"Schneider Electric A9N1P20DIN Acti9 xC60 miniature circuit-breaker, 20 A rated, D curve, 1-pole, 10 kA breaking capacity at 240 V AC, IS/IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC DC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"20 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 12...48 V DC 60 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA conforming to IS/IEC 60947-2 - 12...48 V DC 6 kA conforming to IS/IEC 60947-2 - 60 V DC 7.5 kA conforming to IS/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N1P20DIN/miniature-circuit-breaker-mcb-acti9-xc60-1p-20a-d-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N1P20DIN/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N1P20DIN and how is it quoted?","answer":"The A9N1P20DIN is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9N1P20DIN?","answer":"Breaking capacity is 10 kA Icu at 220…240 V AC 50/60 Hz, 15 kA Icu at 12…48 V DC, and 6 kA Icu at 60 V DC, all per IS/IEC 60947-2."},{"question":"What standards does A9N1P20DIN comply with?","answer":"The A9N1P20DIN complies with IS/IEC 60947-2, with tropicalisation class 2 per IEC 60068-1 and limitation class 3 per IS/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N1P20DIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N1P20DIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}