{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N1P25DIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N1P25DIN","canonicalUrl":"https://aoctrl.com/schneider/A9N1P25DIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N1P25DIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P25DIN, 1-pole, D-curve, 25 A rated current, 10 kA breaking capacity at 240 V AC, clip-on 35 mm DIN rail mount.","salesMarkdown":"## 25 A D-curve MCB for distribution boards The Schneider Electric A9N1P25DIN is a 1-pole miniature circuit breaker from the Acti9 xC60 range, rated 25 A with a D-curve magnetic trip characteristic. The D-curve trips magnetically at 12 x In ±20 % — meaning instantaneous trip between 240 A and 360 A — which suits loads with high inrush current such as small motors, transformers, or solenoid banks where a B- or C-curve would nuisance-trip on startup. Breaking capacity is 10 kA Icu at 220…240 V AC 50/60 Hz per IS/IEC 60947-2, and 15 kA Icu at 12…48 V DC, so it clears fault currents up to those levels without cascading upstream. The thermal-magnetic trip unit covers overload and short-circuit protection on a single pole. Depth is 77.5 mm, height 85 mm — fits standard distribution board enclosures with a 35 mm rail and adequate front clearance for the toggle actuator. IP20 finger-safe protection on the front face; pollution degree 3 per the standard.","metaTitle":"Schneider Electric A9N1P25DIN Acti9 xC60 MCB, D-Curve, 25 A,","metaDescription":"Schneider Electric A9N1P25DIN Acti9 xC60 miniature circuit breaker, 25 A, D-curve, 1-pole, 10 kA breaking capacity at 240 V AC. IS/IEC 60947-2. Active production. Available to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"DC AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"25 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 12...48 V DC 60 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA conforming to IS/IEC 60947-2 - 12...48 V DC 6 kA conforming to IS/IEC 60947-2 - 60 V DC 7.5 kA conforming to IS/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N1P25DIN/miniature-circuit-breaker-mcb-acti9-xc60-1p-25a-d-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N1P25DIN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9N1P25DIN?","answer":"The breaking capacity is 10 kA Icu at 220…240 V AC 50/60 Hz, 15 kA Icu at 12…48 V DC, and 6 kA Icu at 60 V DC, all conforming to IS/IEC 60947-2."},{"question":"Where can I buy the A9N1P25DIN?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Current pricing and availability are confirmed at the time of quote."},{"question":"What standards does the A9N1P25DIN comply with?","answer":"It complies with IS/IEC 60947-2, with limitation class 3 and pollution degree 3. It is also suitable for isolation per that standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N1P25DIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N1P25DIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}