{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N1P40BGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N1P40BGN","canonicalUrl":"https://aoctrl.com/schneider/A9N1P40BGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N1P40BGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N1P40BGN, 1-pole, 40 A, B-curve, 10 kA breaking capacity at 240 V AC, clip-on 35 mm DIN rail mount.","salesMarkdown":"The Schneider Electric A9N1P40BGN is an Acti9 xC60 miniature circuit-breaker, 1-pole, rated 40 A with a B-curve magnetic trip characteristic (3...5 × In). Breaking capacity is 10 kA Icn at 240 V AC 50/60 Hz per IS/IEC 60898-1. The thermal-magnetic trip unit covers distribution applications. The 40 A rating and B-curve mean the breaker holds at 40 A continuous load and trips magnetically between 120 A and 200 A (3–5 × In), which suits general-purpose lighting and socket-outlet circuits where inrush is modest. The 1-pole form factor clips onto a 35 mm DIN rail and occupies 18 mm (2 × 9 mm pitches) in the enclosure. Designed and tested to IS/IEC 60898-1, the Indian-standard adoption of the IEC 60898-1 for miniature circuit-breakers. Limitation class 3 per IS/IEC 60898-1. Earth-leakage protection is via a separate block (not integrated).","metaTitle":"Schneider Electric A9N1P40BGN Acti9 xC60 MCB, 40 A, 1P, B-Cu","metaDescription":"Schneider Electric A9N1P40BGN Acti9 xC60 miniature circuit-breaker, 40 A, 1-pole, B-curve, 10 kA breaking capacity at 240 V AC. IS/IEC 60898-1. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m","Device application":"Distribution","[In] rated current":"40 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Biconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid","IP degree of protection":"IP20","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N1P40BGN/miniature-circuit-breaker-mcb-acti9-xc60-1p-40a-b-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N1P40BGN/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N1P40BGN and how do I get a price?","answer":"The A9N1P40BGN is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate."},{"question":"What is A9N1P40BGN's listed depth?","answer":"The depth is 77.5 mm, which fits standard 35 mm DIN-rail enclosures with adequate wiring space behind the breaker."},{"question":"What is the Acti9 range?","answer":"Acti9 is Schneider Electric's modular DIN-rail miniature circuit-breaker and distribution product family. The A9N1P40BGN is an xC60 model within that range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N1P40BGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N1P40BGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}