{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N21560","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N21560","canonicalUrl":"https://aoctrl.com/schneider/A9N21560","factsUrl":"https://aoctrl.com/api/mcp/products/A9N21560","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Clario iDPN N miniature circuit breaker, A9N21560, 32 A rated current, C-curve, 1P+N, breaking capacity 10 kA Icu at 230 V AC (IEC 60947-2) / 6000 A Icn (EN/IEC 60898-1), clip-on DIN rail mount.","salesMarkdown":"Rated breaking capacity is 10 kA Icu at 230 V AC per IEC 60947-2 and 6000 A Icn at 230 V AC per EN/IEC 60898-1 — enough to handle most utility-side fault levels in a standard domestic or small commercial installation. Certified to both EN/IEC 60898-1 (domestic MCB standard) and EN/IEC 60947-2 (industrial CB standard), so it is accepted in residential panels and light industrial switchgear alike. Neutral on the left, tunnel terminals accept 0.33–10 mm² flexible or 0.75–16 mm² rigid. Tightening torque 2 N·m, strip length 13 mm. IP20 finger-safe when installed in an enclosure. Earth-leakage protection requires a separate block — not integrated. Suitable for isolation per the manufacturer, with ON/OFF local indication on the toggle.","metaTitle":"Schneider Electric A9N21560 iDPN N MCB, 32 A, C-Curve, 1P+N,","metaDescription":"Schneider Electric A9N21560 iDPN N miniature circuit breaker, 32 A rated current, C-curve, 1P+N, breaking capacity 10 kA (IEC 60947-2) / 6000 A (EN/IEC 60898-1). Clip-on DIN rail m","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78 mm","Range":"Clario","Width":"18 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1 EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"IDPN","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60947-1","Range of product":"Clario","Breaking capacity":"10 kA Icu at 230 V AC 50/60 Hz conforming to IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iDPN N","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"32 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm","Connections - terminals":"Tunnel type terminals downstream 0.33...10 mm² flexible Tunnel type terminals downstream 0.75...16 mm² rigid Tunnel type terminals upstream 0.33...10 mm² flexible Tunnel type terminals upstream 0.75...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"400 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230 V AC 50/60 Hz between phase and neutral","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icn at 230 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4c686899cd6877a6a829462e47aaa3a1.pdf","sourceUrl":"https://www.se.com/nl/en/product/A9N21560/idpn-circuit-breaker-idpn-n-1p-+-n-32a-c-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N21560/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N21560?","answer":"Breaking capacity is 10 kA Icu at 230 V AC per IEC 60947-2 and 6000 A Icn at 230 V AC per EN/IEC 60898-1."},{"question":"Where can I buy A9N21560?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N21560","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N21560 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}