{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N21565","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N21565","canonicalUrl":"https://aoctrl.com/schneider/A9N21565","factsUrl":"https://aoctrl.com/api/mcp/products/A9N21565","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Clario iDPN N, miniature circuit-breaker, 1P+N, 6 A, D curve, 6 kA Icn at 230 V AC, thermal-magnetic, clip-on DIN rail mount.","salesMarkdown":"The D curve means the magnetic trip fires between 10 and 14 times the rated current (60 to 84 A), so this breaker is sized for loads with a high inrush, like small motors, transformers, or lighting ballasts that would nuisance-trip a B or C curve. The 6 kA breaking capacity at 230 V AC (per EN/IEC 60898-1) covers most final-subcircuit fault levels in standard domestic and commercial installations; if your prospective short-circuit current exceeds that, you'd step up to a higher-rated upstream device or move to an industrial-pattern MCB. Clip-on mounting to DIN rail, 18 mm width (2 x 9 mm pitches). Tunnel-type terminals accept 0.75…16 mm² rigid or 0.33…10 mm² flexible upstream and downstream. The neutral is on the left, toggle control on the protected pole.","metaTitle":"Schneider Electric A9N21565 iDPN N MCB, 6 A, Curve D, 1P+N,","metaDescription":"Schneider Electric A9N21565 iDPN N miniature circuit breaker, 6 A rated, D-curve, 1P+N, 6 kA breaking capacity per EN/IEC 60898-1. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78 mm","Range":"Clario","Width":"18 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"IDPN","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60947-1","Range of product":"Clario","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iDPN N","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"6 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm","Connections - terminals":"Tunnel type terminals downstream 0.33...10 mm² flexible Tunnel type terminals downstream 0.75...16 mm² rigid Tunnel type terminals upstream 0.33...10 mm² flexible Tunnel type terminals upstream 0.75...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"400 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230 V AC 50/60 Hz between phase and neutral","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","[Uimp] rated impulse withstand voltage":"4 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9N21565/idpn-circuit-breaker-idpn-n-1p-+-n-6a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N21565/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N21565?","answer":"It's rated 6000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 60898-1."},{"question":"What does the D curve mean on this MCB?","answer":"The magnetic trip operates between 10 and 14 times the rated current (60–84 A for the 6 A unit), making it suitable for loads with high inrush current that would cause nuisance tripping on a B or C curve."},{"question":"Where can I buy A9N21565 and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N21565","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N21565 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}