{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N26477","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N26477","canonicalUrl":"https://aoctrl.com/schneider/A9N26477","factsUrl":"https://aoctrl.com/api/mcp/products/A9N26477","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 MX shunt trip release, 48 V AC/DC control voltage, 18 mm wide, 73.5 mm deep, EN/IEC 60947-2, obsolete.","salesMarkdown":"It sits downstream of the breaker's trip mechanism; when you apply 48 V AC or DC to its control circuit, it mechanically trips the host breaker, giving you a remote emergency-stop or interlock function without running power wiring through the breaker itself. The control circuit draws its power from a separate source, not the breaker's load path. Mounts on a 35 mm symmetrical DIN rail, occupies 18 mm of panel width (one modular pitch), and the depth is 73.5 mm — standard for the Acti9 accessory footprint. The white housing carries a mechanical action indicator so you can see the trip state at a glance. ## Lifecycle reality — obsolete, not gone No official Schneider successor order code exists for this shunt trip variant. The 48 V control voltage is the key fit parameter — it must match your trip-signal source. The part works on both AC and DC at that same voltage, which simplifies wiring in mixed-supply panels. The 18 mm width means it takes one standard DIN-rail pitch; if your panel is tight, that's one less modular slot than a two-pitch accessory. EN/IEC 60947-2 is the standard for low-voltage switchgear and controlgear — specifically the section covering circuit-breaker accessories. That certification tells you the shunt trip has been type-tested for coordination with the host breaker, so you don't lose selectivity or breaking capacity when you add it. The bottom screw-clamp terminals accept 0.5 to 2.5 mm² rigid or 1.5 mm² flexible (with or without ferrule), with a stripping length of 9 mm and a tightening torque of 1 N·m. That's standard for control wiring in a panel — no special tooling needed.","metaTitle":"Schneider Electric A9N26477 Acti9 MX Shunt Trip, 48V AC/DC,","metaDescription":"Schneider Electric A9N26477 Acti9 MX shunt trip release, 48 V AC/DC control voltage. Obsolete — sourced to order against RFQ. EN/IEC 60947-2. 18 mm wide, DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White","Depth":"73.5 mm","Width":"18 mm","Height":"82.5 mm","Coil Voltage":"48 V AC 50/60 Hz 48 V DC","Product Status":"Active","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"50 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Shunt trip release","Ambient Air Temperature Operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$136.62","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a2077bfbf1624c899d4ad752dff80e29.pdf","sourceUrl":"https://www.se.com/id/en/product/A9N26477/mx-shunt-trip-48vac-48vdc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N26477/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N26477","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N26477 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}