{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N26613","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N26613","canonicalUrl":"https://aoctrl.com/schneider/A9N26613","factsUrl":"https://aoctrl.com/api/mcp/products/A9N26613","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi xC60 add-on residual current device, A9N26613, 2P, 63 A, 300 mA, Type AC, instantaneous, voltage-independent electromechanical, clip-on DIN rail mount, IP20/IP40.","salesMarkdown":"The A9N26613 is a Vigi xC60 add-on residual current device from the Acti9 range, designed to clip onto the outgoing side of a compatible MCB to provide earth leakage protection. The tripping mechanism is voltage-independent electromechanical, so it clears a ground fault even if the phase voltage collapses. The 63 A rated current and 300 mA sensitivity set the protection threshold for the outgoing circuit. Type AC earth leakage protection covers sinusoidal AC residual currents — standard for general-purpose socket circuits, lighting, and resistive loads, but not for loads with power electronics that generate pulsed or DC fault currents. The instantaneous time delay means it trips without intentional delay, so it coordinates with upstream time-delayed RCDs only if the upstream device has a higher rating or a deliberate S-type delay. The 6 kV impulse withstand voltage (Uimp) and pollution degree 3 rating confirm it is suitable for fixed installations in environments with conductive pollution, typical of distribution boards and industrial control panels. Clip-on mounting on DIN rail, 4 modules wide at 9 mm pitch (72 mm total). The bottom tunnel terminals accept 1...35 mm² rigid or 1...25 mm² flexible conductors; strip length is 14 mm, tightening torque 3.5 N.m. Electrical connection to the upstream MCB is by screws — it physically couples to the outgoing side of a compatible Acti9 MCB, forming a combined RCBO assembly. The red indicator on the front face shows tripped status. IP20 on the body, IP40 inside the modular enclosure — suitable for dry indoor panel environments.","metaTitle":"A9N26613 Vigi xC60 Add-on RCD, 2P 63A 300mA AC, Obsolete","metaDescription":"A9N26613 is an obsolete Acti9 Vigi xC60 add-on residual current device, 2P, 63A, 300mA, Type AC. Sourced to order against RFQ through independent distribution.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74.5 mm","Range":"Acti9","Width":"72 mm","Height":"87 mm","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","9 Mm Pitches":"4","Network type":"AC","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Red indicator light on the front face","Mounting support":"DIN rail","Pollution degree":"3","Device short name":"Vigi xC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","[Ue] rated operational voltage":"230...240 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...240 V conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent Electromechanical","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N26613/vigi-xc60-earth-leakage-addon-block-2p-63a-ac-300ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N26613/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N26613 and how is it quoted?","answer":"We source the A9N26613 through independent distribution channels — new-old-stock or verified surplus — and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest alternative to A9N26613?","answer":"No official successor order code is listed in the record. A functionally similar replacement would need to match the 2P, 63 A, 300 mA, Type AC, voltage-independent electromechanical profile, but the specific mechanical coupling to the upstream MCB must be verified against the panel hardware."},{"question":"What compliance documentation does Schneider Electric provide for A9N26613?","answer":"The A9N26613 is certified to EN/IEC 61009-2-1 and EN/IEC 61009-1. The IP ratings conform to IEC 60529. Documentation typically includes the declaration of conformity and test reports per these standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N26613","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N26613 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}