{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N26643","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N26643","canonicalUrl":"https://aoctrl.com/schneider/A9N26643","factsUrl":"https://aoctrl.com/api/mcp/products/A9N26643","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi xC60 add-on residual current device, 4P, 63 A, 30 mA Type AC, clip-on DIN rail, A9N26643.","salesMarkdown":"The Schneider Electric A9N26643 is a Vigi xC60 add-on residual current device (RCD) from the Acti9 range, designed to clip onto the outgoing side of a compatible MCB to provide earth-leakage protection in a 4-pole, 63 A circuit on a 400...415 V AC network. It is a voltage-independent, electromechanical device with a 30 mA sensitivity (Type AC, instantaneous trip), meaning it detects sinusoidal AC earth faults and disconnects the circuit without needing an external power supply for the trip coil — a key reliability feature for critical protection paths. Clip-on mounting to DIN rail, 7 x 9 mm pitches wide (135 mm), 87 mm tall, 74.5 mm deep. The bottom tunnel terminals accept 1...35 mm² rigid or 1...25 mm² flexible conductors, stripped 14 mm, torqued to 3.5 N·m. IP20 finger-safe on the front, IP40 inside a modular enclosure. The red indicator on the front face shows tripped status for quick visual fault isolation on the panel door. Compliant with EN/IEC 61009-1 and EN/IEC 61009-2-1 — the harmonized standards for residual current operated circuit-breakers with integral overcurrent protection. The 8/20 µs impulse withstand of 250 A covers surge coordination in typical industrial distribution.","metaTitle":"A9N26643 Vigi xC60 4P 63A 30mA Type AC RCD Add-On Block","metaDescription":"A9N26643 Vigi xC60 add-on residual current device, 4P, 63A, 30mA Type AC, clip-on DIN rail. Active production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"74.5 mm","Range":"Acti9","Width":"135 mm","Height":"87 mm","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","9 Mm Pitches":"7","Network type":"AC","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Red indicator light on the front face","Mounting support":"DIN rail","Pollution degree":"3","Device short name":"Vigi xC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m bottom","[In] rated current":"63 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"By screws","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","[Ue] rated operational voltage":"400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Electromechanical Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N26643/vigi-xc60-earth-leakage-addon-block-4p-63a-ac-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N26643/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N26643 and what is the lead time?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment on your BOM line."},{"question":"What compliance documentation does A9N26643 carry?","answer":"The A9N26643 is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. It carries IP20 and IP40 ratings per IEC 60529. Full RoHS and REACH declarations are available from the manufacturer's documentation portal for this Acti9 series part."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N26643","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N26643 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}