{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N2P06BIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N2P06BIN","canonicalUrl":"https://aoctrl.com/schneider/A9N2P06BIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N2P06BIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N2P06BIN, 6 A, B curve, 2P, 10 kA at 380-415 V AC, thermal-magnetic, clip-on 35 mm DIN rail, IP20, white.","salesMarkdown":"The Schneider Electric A9N2P06BIN is an Acti9 xC60 miniature circuit-breaker (MCB) rated at 6 A with a B curve, designed for distribution applications in residential and commercial panels. Its 10 kA breaking capacity at 380-415 V AC (IS/IEC 60947-2) handles typical fault levels on 400 V networks — enough to interrupt a hard short without cascading upstream. The 2-pole configuration protects both phase and neutral, and the thermal-magnetic trip unit responds to overloads (thermal) and short-circuits (magnetic) with the B curve tripping between 3 and 5 times rated current, so it's a good fit for lighting and general-purpose socket circuits where inrush is low. The 36 mm width occupies 4 x 9 mm pitches, so it fits neatly into a 4-module slot in a consumer unit or distribution board. Depth of 77.5 mm and height of 85 mm leave clearance for wiring and enclosure depth. Tunnel terminals at the bottom accept up to 25 mm² rigid or 16 mm² flexible cable; strip length is 13 mm. The 6 kA Icu at 100-125 V DC covers DC circuits like control power supplies or battery-backed loads. Overvoltage category IV means it's rated for installation at the origin of the installation (utility meter side), not just downstream sub-distribution. The B curve with magnetic tripping at 4 x In ±20% means it holds steady through normal inrush from resistive loads but trips fast on a short — good for lighting, socket outlets, and general-purpose circuits.","metaTitle":"Schneider Electric A9N2P06BIN Acti9 xC60 MCB, 6 A, B Curve,","metaDescription":"Schneider Electric A9N2P06BIN Acti9 xC60 miniature circuit-breaker, 6 A rated current, B curve, 10 kA breaking capacity at 380-415 V AC, 2-pole, thermal-magnetic trip, clip-on 35 m","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"6 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"6 kA conforming to IS/IEC 60947-2 - 100...125 V DC 7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N2P06BIN/miniature-circuit-breaker-mcb-acti9-xc60-2p-6a-b-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N2P06BIN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9N2P06BIN?","answer":"10 kA Icn at 380-415 V AC and 6 kA Icu at 100-125 V DC, both conforming to IS/IEC 60947-2. That covers typical fault levels on 400 V three-phase networks and DC control circuits."},{"question":"What is the closest alternative to the A9N2P06BIN in the Acti9 family?","answer":"The A9N2P06BIN is a 2-pole 6 A B-curve MCB. The closest sibling in the same Acti9 xC60 series would be a different current rating (e.g., 10 A or 16 A) or a different curve (C or D) depending on the load type. No pin-compatible drop-in with identical ratings exists; the decision hinges on the required trip curve and ampacity for the circuit."},{"question":"Where can I buy the A9N2P06BIN and what is the lead time?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery window."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N2P06BIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N2P06BIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}