{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N2P06CIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N2P06CIN","canonicalUrl":"https://aoctrl.com/schneider/A9N2P06CIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N2P06CIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N2P06CIN, 2P, 6 A rated current, C curve, 10 kA breaking capacity at 415 V AC, clip-on DIN rail mount, IP20.","salesMarkdown":"The A9N2P06CIN is a 2-pole Acti9 xC60 miniature circuit-breaker rated at 6 A with a C curve — the standard choice for general-purpose distribution and moderate inrush loads like small motors or lighting banks. Clip-on mounting on 35 mm DIN rail (4 module pitches, 36 mm wide) makes it a direct drop-in for Acti9 or legacy Multi9 boards. ## Integration & compliance Rated for isolation (IS/IEC 60947-2) with clear ON/OFF indication on the toggle. The IP20 finger-safe front keeps live terminals covered once installed. Biconnect bottom terminals allow daisy-chaining without piggyback links — saves a few minutes per panel on multi-pole runs.","metaTitle":"A9N2P06CIN Miniature Circuit-Breaker, Acti9 xC60, 6 A, C Cur","metaDescription":"A9N2P06CIN Acti9 xC60 MCB, 6 A, C curve, 10 kA breaking capacity at 415 V AC, 2P, DIN rail mount. IS/IEC 60947-2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"6 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"6 kA conforming to IS/IEC 60947-2 - 100...125 V DC 7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N2P06CIN/miniature-circuit-breaker-mcb-acti9-xc60-2p-6a-c-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N2P06CIN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N2P06CIN?","answer":"10 kA Icn at 380–415 V AC 50/60 Hz per IS/IEC 60947-2, and 6 kA Icu at 100–125 V DC per the same standard."},{"question":"Where can I buy A9N2P06CIN?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Schneider provide for A9N2P06CIN?","answer":"The MCB is certified to IS/IEC 60947-2 and carries tropicalisation class 2 per IEC 60068-1. Standard Schneider documentation includes the declaration of conformity and test reports; specific RoHS/REACH/UL statements should be requested at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N2P06CIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N2P06CIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}