{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N2P06DGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N2P06DGN","canonicalUrl":"https://aoctrl.com/schneider/A9N2P06DGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N2P06DGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P06DGN, D curve, 6 A rated, 2-pole, 10 kA breaking capacity, clip-on 35 mm DIN rail mount.","salesMarkdown":"Breaking capacity is 10 kA Icn at both 240 V and 415 V AC, certified to IS/IEC 60898-1. Occupies 4 x 9 mm pitches = 36 mm width, with a depth of 77.5 mm and height of 85 mm. Standard modular footprint for a 2P MCB fits any 36 mm-wide slot in a distribution board. Biconnect terminals on the bottom allow daisy-chaining or feed-through without additional connectors. IP20 finger-safe protection on the front. Relative humidity tolerance is 95% at 55 °C. Overvoltage category IV, suitable for installation at the origin of the installation (utility side of the main distribution board). Earth-leakage protection requires a separate block (not integrated). Electrical and mechanical durability rated at 20,000 cycles each. ON/OFF indication via toggle position. White colour housing is standard for the Acti9 range.","metaTitle":"Schneider Electric A9N2P06DGN Acti9 xC60 MCB, D Curve, 6 A,","metaDescription":"Schneider Electric A9N2P06DGN Acti9 xC60 miniature circuit breaker, D curve, 6 A, 2-pole, 10 kA breaking capacity, clip-on DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"6 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N2P06DGN/miniature-circuit-breaker-mcb-acti9-xc60-2p-6a-d-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N2P06DGN/alternatives.json"},"ai":{"faq":[{"question":"What is the D curve used for on this MCB?","answer":"The D curve (magnetic trip 10–14 x In) is designed for loads with high inrush currents — motors, transformers, welding equipment, or large capacitor banks — where a B or C curve would trip on startup surge."},{"question":"What compliance documentation does Schneider provide for A9N2P06DGN?","answer":"The part is certified to IS/IEC 60898-1 and carries tropicalisation class 2 per IEC 60068-1. Standard Schneider documentation includes the declaration of conformity and test certificates available through their product support portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N2P06DGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N2P06DGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}