{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N2P06DIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N2P06DIN","canonicalUrl":"https://aoctrl.com/schneider/A9N2P06DIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N2P06DIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N2P06DIN, D curve, 6 A, 2 poles, 10 kA breaking capacity at 415 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N2P06DIN is an Acti9 xC60 miniature circuit-breaker — a thermal-magnetic MCB with a D trip curve, rated 6 A, 2 poles, and a breaking capacity of 10 kA at 380–415 V AC (IS/IEC 60947-2). It clips onto a 35 mm DIN rail, occupies 4 x 9 mm pitches (36 mm wide), and carries IP20 finger-safe terminals. The A9N2P06DIN is listed as current production. ## Integration & panel fit The 36 mm width (4 x 9 mm pitches) and 77.5 mm depth fit standard distribution boards; the white housing and toggle actuator give clear ON/OFF indication. ## Standards & approvals Certified to IS/IEC 60947-2, utilisation category A. Limitation class 3. Suitable for isolation per the same standard. Earth-leakage protection requires a separate block. Electrical and mechanical durability rated at 20,000 cycles each.","metaTitle":"Schneider Electric A9N2P06DIN Acti9 xC60 MCB, D Curve, 6 A,","metaDescription":"Schneider Electric A9N2P06DIN Acti9 xC60 miniature circuit-breaker. D curve, 6 A rated, 2 poles, 10 kA breaking capacity at 415 V AC. IS/IEC 60947-2. Current production. Quoted to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"6 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"6 kA conforming to IS/IEC 60947-2 - 100...125 V DC 7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N2P06DIN/miniature-circuit-breaker-mcb-acti9-xc60-2p-6a-d-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N2P06DIN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N2P06DIN?","answer":"10 kA at 380–415 V AC (IS/IEC 60947-2) and 6 kA at 100–125 V DC."},{"question":"What does the D curve mean on this MCB?","answer":"Magnetic tripping is set at 12 x In (±20%), so it handles high inrush currents from motor or transformer loads without nuisance tripping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N2P06DIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N2P06DIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}