{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N2P10DGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N2P10DGN","canonicalUrl":"https://aoctrl.com/schneider/A9N2P10DGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N2P10DGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 series, A9N2P10DGN miniature circuit breaker, 2P, 10 A, D curve, 10 kA Icn at 415 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N2P10DGN is a 2-pole miniature circuit breaker from the Acti9 xC60 family, rated 10 A with a D tripping curve. It protects final subcircuits against overload and short-circuit in AC distribution boards, per IS/IEC 60898-1. The D curve means magnetic tripping occurs at 10 to 14 times rated current (100–140 A instantaneous), so it handles the inrush of motor loads, transformers, or welding equipment without nuisance trips. For a 10 A breaker, that's a solid 100–140 A magnetic pickup — sized for high-starting-current circuits. Breaking capacity is 10 kA Icn at both 240 V and 415 V AC (50/60 Hz), certified to IS/IEC 60898-1. Occupies two pole positions in a standard distribution board. Height 85 mm, depth 77.5 mm — fits flush in a residential or commercial enclosure with a transparent door. Biconnect feature allows daisy-chaining outgoing circuits without a separate distribution block. Thermal-magnetic trip unit: the thermal bimetal protects against sustained overload (heating), the solenoid handles short-circuit. Rated operational voltage 220–240 V AC or 380–415 V AC, 50/60 Hz. Overvoltage category IV — suitable for main incoming supply at the service entrance, not just downstream subcircuits. Electrical and mechanical durability both rated at 20,000 cycles — typical for a distribution MCB; not intended for frequent switching duty (use a contactor or switch-disconnector for that). Earth-leakage protection requires a separate RCCB block (not integrated). The MCB itself provides overcurrent and short-circuit protection only.","metaTitle":"Schneider Electric A9N2P10DGN Acti9 xC60 MCB, 10A D Curve 2P","metaDescription":"Schneider Electric A9N2P10DGN Acti9 xC60 miniature circuit breaker, 10A rated current, D curve, 2 poles, 10kA breaking capacity per IS/IEC 60898-1. Active production. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N2P10DGN/miniature-circuit-breaker-mcb-acti9-xc60-2p-10a-d-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N2P10DGN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N2P10DGN?","answer":"The A9N2P10DGN has a breaking capacity of 10,000 A Icn at both 240 V AC and 415 V AC (50/60 Hz), certified to IS/IEC 60898-1."},{"question":"What compliance documentation does Schneider provide for A9N2P10DGN?","answer":"The A9N2P10DGN is certified to IS/IEC 60898-1. It carries tropicalisation class 2 per IEC 60068-1. For RoHS, REACH, and other compliance documentation, request the manufacturer's declaration at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N2P10DGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N2P10DGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}