{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N3P06DGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N3P06DGN","canonicalUrl":"https://aoctrl.com/schneider/A9N3P06DGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N3P06DGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N3P06DGN, 3-pole, 6 A rated, D-curve, 10 kA breaking capacity, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N3P06DGN is an Acti9 xC60 miniature circuit-breaker — a 3-pole, 6 A thermal-magnetic MCB with a D-curve trip characteristic, designed for distribution boards on 35 mm DIN rail. Rated 6 A with a D-curve (magnetic trip 10…14 × In), it handles high inrush loads like motor starters and transformers where a B- or C-curve would nuisance-trip on startup. Breaking capacity hits 10 kA Icn at both 240 V and 415 V AC (50/60 Hz), certified to IS/IEC 60898-1, limitation class 3 — meaning it clips the let-through energy enough to protect downstream wiring in a fault. Rated operational voltage is 220…240 V AC or 380…415 V AC, so it covers single-phase and three-phase distribution in the same footprint. Clip-on mounting to a 35 mm DIN rail, 54 mm wide (6 × 9 mm pitches), 85 mm tall, 77.5 mm deep — standard panel footprint that fits alongside other Acti9 modular devices. Biconnect terminals allow daisy-chaining without extra links. IP20 finger-safe front; pollution degree 3, overvoltage category IV — rated for the dirty, surge-prone environment of a main distribution board. Compliance documentation includes IS/IEC 60898-1 certification and tropicalisation per IEC 60068-1 (2 levels). RoHS, REACH, and other EU directives are standard for the Acti9 range — request the declaration at quote.","metaTitle":"Schneider Electric A9N3P06DGN Acti9 xC60 MCB, 6 A D-curve, 3","metaDescription":"Schneider Electric A9N3P06DGN Acti9 xC60 miniature circuit-breaker, 6 A rated, D-curve, 3-pole, 10 kA breaking capacity, IS/IEC 60898-1. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"6 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"10...14 x In","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N3P06DGN/miniature-circuit-breaker-mcb-acti9-xc60-3p-6a-d-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N3P06DGN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N3P06DGN?","answer":"10 kA Icn at both 240 V and 415 V AC (50/60 Hz) per IS/IEC 60898-1, limitation class 3."},{"question":"Where can I buy A9N3P06DGN?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."},{"question":"What is the D-curve trip range on this MCB?","answer":"Magnetic tripping occurs at 10…14 × In (60…84 A), suited for loads with high inrush current."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N3P06DGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N3P06DGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}