{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N3P10BGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N3P10BGN","canonicalUrl":"https://aoctrl.com/schneider/A9N3P10BGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N3P10BGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60, miniature circuit breaker, A9N3P10BGN, 10 A, B curve, 3P, 10 kA Icn, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N3P10BGN is an Acti9 xC60 miniature circuit breaker — a thermal-magnetic MCB rated 10 A, B-curve, 3-pole, designed for distribution boards on 35 mm DIN rail. It clips onto the rail and occupies 6 x 9 mm pitches (54 mm wide). The 10 kA Icn at 240 V and 415 V AC (per IS/IEC 60898-1) covers most commercial and light industrial fault levels; the limitation class 3 rating means it limits let-through energy well enough to coordinate with downstream equipment. Rated current 10 A is the continuous load it carries at 30 °C ambient without tripping. The thermal-magnetic trip unit responds to sustained overloads (thermal bimetal) and short-circuits (solenoid). Magnetic tripping between 3 and 5 x In means the breaker holds motor inrush from small contactor coils and power supplies but clears a hard fault fast. Breaking capacity 10,000 A Icn at both 240 V and 415 V AC — that is the maximum prospective fault current it can interrupt without welding or exploding. For most distribution panels fed from a 200 kVA transformer or smaller, that is adequate headroom. The rated operational voltage covers 220–240 V and 380–415 V AC, 50/60 Hz, so it works on single-phase and three-phase networks within those bands. ## Integration notes IP20 finger-safe front, pollution degree 3 (conductive pollution expected in industrial enclosures). The white housing with toggle ON/OFF indication is standard for Acti9 panels.","metaTitle":"Schneider Electric A9N3P10BGN Acti9 xC60 MCB, 10A, B Curve,","metaDescription":"Schneider Electric A9N3P10BGN Acti9 xC60 miniature circuit breaker, 10 A rated current, B curve, 3 poles, 10 kA breaking capacity per IS/IEC 60898-1. Current production. Sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"B","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N3P10BGN/miniature-circuit-breaker-mcb-acti9-xc60-3p-10a-b-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N3P10BGN/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for A9N3P10BGN?","answer":"This part is sourced to order against an RFQ through our independent distribution channel. Submit a request and we will confirm current pricing and availability at quote time."},{"question":"What is the breaking capacity of A9N3P10BGN?","answer":"It is rated 10,000 A Icn at both 240 V AC and 415 V AC, 50/60 Hz, conforming to IS/IEC 60898-1."},{"question":"What compliance documentation is available for A9N3P10BGN?","answer":"The breaker is certified to IS/IEC 60898-1 and carries tropicalisation class 2 per IEC 60068-1. For specific RoHS, REACH, or UL declarations, the manufacturer provides compliance documentation upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N3P10BGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N3P10BGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}