{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N3P10DIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N3P10DIN","canonicalUrl":"https://aoctrl.com/schneider/A9N3P10DIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N3P10DIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60, A9N3P10DIN, miniature circuit breaker, 3P, 10 A, D curve, 10 kA at 415 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N3P10DIN is an Acti9 xC60 miniature circuit breaker rated 10 A with a D tripping curve, three protected poles, and a breaking capacity of 10 kA Inc at 380–415 V AC 50/60 Hz per IS/IEC 60947-2. Same part, different passport — this is the standard Indian-market variant (IS/IEC), but the hardware is identical to the European iC60N range. Genuine is genuine; the only difference is the standard marking on the nameplate. ## D-curve trip and what it means on the line The D curve magnetic trip is set at 12 x In ±20 %, meaning the instantaneous trip threshold is 120 A nominal. That deliberate gap above the C curve (5–10 x In) is sized for transformer inrush, motor starting, or welding equipment — loads that pull a short-duration surge well above running current without being a fault. For a 10 A MCB on a 3P distribution board feeding small motor groups or control transformers, this avoids nuisance trips on energisation. The 54 mm width (9 mm pitch × 6) is the standard 3P MCB footprint — three modules wide. Depth 77.5 mm, height 85 mm. Biconnect bottom terminals allow daisy-chaining without separate distribution blocks. Tightening torque 2 N·m; strip length 13 mm. Rated for isolation (suitability for isolation: Yes per IS/IEC 60947-2). Pollution degree 3, overvoltage category IV. IP20 finger-safe terminals. Relative humidity 95 % at 55 °C. The standard marking is IS/IEC 60947-2; the same hardware carries CE and UKCA for European markets — the nameplate differs, not the internals.","metaTitle":"Schneider Electric A9N3P10DIN Acti9 xC60 MCB, D Curve, 10 A,","metaDescription":"Schneider Electric A9N3P10DIN Acti9 xC60 miniature circuit breaker, 10 A rated current, D curve, 3 poles, 10 kA breaking capacity at 415 V AC. IS/IEC 60947-2. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC DC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA conforming to IS/IEC 60947-2 - 100...125 V DC","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N3P10DIN/miniature-circuit-breaker-mcb-acti9-xc60-3p-10a-d-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N3P10DIN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N3P10DIN?","answer":"10 kA Inc at 380–415 V AC 50/60 Hz per IS/IEC 60947-2, and 15 kA Icu at 100–125 V DC."},{"question":"What is the closest alternative to A9N3P10DIN?","answer":"The European-market equivalent is the iC60N D 10 A 3P (Schneider order code A9F74310). Same hardware, same ratings, different standard marking (EN/IEC 60898 vs IS/IEC 60947-2). No pin-compatibility issue — identical footprint and terminal layout."},{"question":"Where can I buy A9N3P10DIN and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N3P10DIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N3P10DIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}