{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N3P25BIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N3P25BIN","canonicalUrl":"https://aoctrl.com/schneider/A9N3P25BIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N3P25BIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit breaker, A9N3P25BIN, 3-pole, 25 A, B curve, 10 kA breaking capacity at 415 V AC, clip-on DIN rail mount.","salesMarkdown":"The Schneider Electric A9N3P25BIN is a three-pole miniature circuit breaker from the Acti9 xC60 line, rated 25 A with a B trip curve. The 10 kA breaking capacity at 380–415 V AC (IS/IEC 60947-2) means it can safely interrupt a fault current up to that level without welding its contacts or venting arc gas into the enclosure — important when the available fault current at the panel is known to be under that threshold. The 25 A continuous rating (In) is the current the breaker carries indefinitely without tripping; it matches the ampacity of the downstream conductors. The B curve means the magnetic trip fires at 4 x In ±20 % — so between roughly 80 and 120 A instantaneously — making it a good fit for resistive or general-purpose loads where inrush is modest (lighting, heaters, small motor control circuits with separate overload protection). The 10 kA Icn at 415 V AC is the rated short-circuit capacity under IS/IEC 60947-2 for a Category A breaker (no intentional short-time delay). That standard also certifies the breaker for isolation — the toggle gives visible open contacts when switched off. Clip-on mounting on 35 mm DIN rail — standard across the Acti9 range. The housing is 54 mm wide (three 18 mm modules), 85 mm tall, 77.5 mm deep, so it takes three 9 mm pitches on the rail. Tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible copper; wire strip length is 13 mm.","metaTitle":"Schneider Electric A9N3P25BIN Acti9 xC60 MCB, 25 A, 3P, B Cu","metaDescription":"Schneider Electric A9N3P25BIN Acti9 xC60 miniature circuit breaker, 25 A rated current, 3 poles, B curve, 10 kA breaking capacity at 415 V AC. IS/IEC 60947-2. Sourced to order. Req","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"B","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC DC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"25 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA conforming to IS/IEC 60947-2 - 100...125 V DC","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N3P25BIN/miniature-circuit-breaker-mcb-acti9-xc60-3p-25a-b-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N3P25BIN/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9N3P25BIN?","answer":"Submit an RFQ against your BOM line. Availability and current pricing are confirmed at quote time through independent distribution."},{"question":"What is the breaking capacity of A9N3P25BIN at 415 V AC?","answer":"The A9N3P25BIN has a 10 kA Icn breaking capacity at 380–415 V AC, 50/60 Hz, certified to IS/IEC 60947-2."},{"question":"What standards does the A9N3P25BIN comply with?","answer":"It complies with IS/IEC 60947-2, which covers low-voltage switchgear and controlgear for circuit breakers, including isolation suitability and pollution degree 3."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N3P25BIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N3P25BIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}