{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N3P32CGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N3P32CGN","canonicalUrl":"https://aoctrl.com/schneider/A9N3P32CGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N3P32CGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 series, miniature circuit breaker, 32 A, 3P, C-curve, 10 kA Icn at 240/415 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"## What it is and what it does The Schneider Electric A9N3P32CGN is an Acti9 xC60 miniature circuit breaker — a thermal-magnetic MCB for AC distribution in commercial and light industrial panels. Rated 32 A on a 3-pole (3P) body, it clips onto a 35 mm DIN rail and occupies 6 x 9 mm pitches (54 mm wide). The C-curve trips magnetically between 5 and 10 times rated current — the standard choice for mixed resistive and moderate inductive loads (lighting, small motors, general socket circuits) where inrush is higher than a B-curve allows but lower than a D-curve needs. Breaking capacity is 10 kA Icn at both 240 V and 415 V AC, certified to IS/IEC 60898-1. That means it can safely interrupt a fault up to 10 kA without welding contacts or rupturing the case — sufficient for most secondary distribution boards fed by a transformer with typical source impedance. ## Integration and panel fit Clip-on mounting on a 35 mm DIN rail — standard for any IEC enclosure. The 54 mm width (3P) and 77.5 mm depth fit alongside other Acti9 devices without spacing issues. Terminals accept up to 35 mm² rigid or 25 mm² flexible; the biconnect bottom terminal allows daisy-chaining busbars or outgoing cables. Tightening torque is 3.5 N·m. Rated operational voltage covers 220–240 V and 380–415 V AC, 50/60 Hz — single-phase or three-phase networks. Pollution degree 3 and overvoltage category IV suit it for main panel incoming positions, not just sub-distribution. IP20 finger-safe terminals; the toggle provides ON/OFF indication. Tropicalisation class 2 per IEC 60068-1 means it handles 95 % RH at 55 °C — fine for unventilated enclosures in humid environments.","metaTitle":"Schneider Electric A9N3P32CGN Acti9 xC60 MCB, 32A, 3P, C-Cur","metaDescription":"Schneider Electric A9N3P32CGN Acti9 xC60 miniature circuit breaker. 32 A rated, 3-pole, C-curve, 10 kA breaking capacity per IS/IEC 60898-1. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Biconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid","IP degree of protection":"IP20","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N3P32CGN/miniature-circuit-breaker-mcb-acti9-xc60-3p-32a-c-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N3P32CGN/alternatives.json"},"ai":{"faq":[{"question":"What standard does the A9N3P32CGN comply with?","answer":"It is certified to IS/IEC 60898-1, the Indian/IEC standard for miniature circuit breakers in household and similar installations."},{"question":"What is the closest alternative to the A9N3P32CGN in the same family?","answer":"Within the Acti9 xC60 range, the closest peer is a 32 A, 3P, C-curve MCB with the same breaking capacity and form factor. The deciding factor between variants is typically the curve code (B, C, or D) and the number of poles — this part is the standard C-curve 3-pole version for general distribution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N3P32CGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N3P32CGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}