{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N3P63DIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N3P63DIN","canonicalUrl":"https://aoctrl.com/schneider/A9N3P63DIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N3P63DIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N3P63DIN, 3P, 63 A rated, D curve, 6 kA breaking capacity at 415 V AC, clip-on 35 mm DIN rail mount.","salesMarkdown":"The Schneider Electric A9N3P63DIN is a 3-pole miniature circuit-breaker from the Acti9 xC60 range, rated at 63 A with a D tripping curve. Breaking capacity is 6 kA Icn at 380–415 V AC (50/60 Hz) and 15 kA Icu at 100–125 V DC, both per IS/IEC 60947-2. The thermal-magnetic trip unit covers overloads (thermal bimetal) and short-circuits (magnetic coil). Limitation class 3 per IS/IEC 60947-2 means it limits let-through energy enough to protect downstream equipment in a fault — a useful detail for coordination studies. Strip length is 13 mm for top or bottom connection. Biconnect bottom terminals allow daisy-chaining without extra links.","metaTitle":"Schneider Electric A9N3P63DIN Acti9 xC60 MCB, 63 A, D Curve,","metaDescription":"Schneider Electric A9N3P63DIN Acti9 xC60 miniature circuit-breaker, 63 A rated, D curve, 3 poles, 6 kA breaking capacity at 415 V AC. IS/IEC 60947-2. Active production. Available t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC DC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"6 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m","Device application":"Distribution","[In] rated current":"63 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Biconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid","IP degree of protection":"IP20","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"6 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA conforming to IS/IEC 60947-2 - 100...125 V DC","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N3P63DIN/miniature-circuit-breaker-mcb-acti9-xc60-3p-63a-d-curve-6ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N3P63DIN/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9N3P63DIN?","answer":"The A9N3P63DIN is sourced to order against an RFQ; current pricing and availability are confirmed at quote time."},{"question":"What is A9N3P63DIN's listed depth (77.5 mm) on this component line?","answer":"The A9N3P63DIN has a depth of 77.5 mm."},{"question":"What is A9N3P63DIN's listed range (Acti9) on this component line?","answer":"The A9N3P63DIN belongs to the Acti9 range of miniature circuit-breakers."},{"question":"What compliance documentation does this brand provide for A9N3P63DIN (RoHS, REACH, UL, IEC)?","answer":"The A9N3P63DIN is certified to IS/IEC 60947-2. The evidence does not list RoHS, REACH, or UL documentation; contact the supplier for full compliance declarations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N3P63DIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N3P63DIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}