{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N4P32CGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N4P32CGN","canonicalUrl":"https://aoctrl.com/schneider/A9N4P32CGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N4P32CGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit breaker, A9N4P32CGN, 32 A rated current, C curve, 10 kA breaking capacity, 4 poles, clip-on 35 mm DIN rail mount, IS/IEC 60898-1.","salesMarkdown":"The Schneider Electric A9N4P32CGN is a 4-pole miniature circuit breaker from the Acti9 xC60 range, rated at 32 A with a C curve and a 10 kA breaking capacity per IS/IEC 60898-1. At 72 mm wide and 85 mm tall, it occupies 8 modules of 9 mm pitch. That's a lot of rail space for a 4-pole breaker — plan your enclosure fill accordingly. The IP20 finger-safe terminals mean it's intended for enclosed distribution boards, not exposed wet areas. Biconnect tunnel terminals accept up to 35 mm² rigid or 25 mm² flexible; strip 13 mm and torque to 3.5 N·m. The toggle gives ON/OFF indication. Certified to IS/IEC 60898-1, the Indian standard for MCBs in household and similar installations. Overvoltage category IV suits it for main distribution board installation, not just sub-circuits.","metaTitle":"A9N4P32CGN Acti9 MCB, 32 A, C Curve, 10 kA, 4P","metaDescription":"Schneider Electric A9N4P32CGN Acti9 xC60 miniature circuit breaker, 32 A rated, C curve, 10 kA breaking capacity at 240 V, 4 poles, IS/IEC 60898-1. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Biconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid","IP degree of protection":"IP20","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N4P32CGN/miniature-circuit-breaker-mcb-acti9-xc60-4p-32a-c-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N4P32CGN/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N4P32CGN?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9N4P32CGN?","answer":"The breaking capacity is 10,000 A Icn at both 240 V AC and 415 V AC, 50/60 Hz, conforming to IS/IEC 60898-1. That's the same at both voltage levels, so no derating needed when moving from 240 V to 415 V."},{"question":"What does the C curve mean on this breaker?","answer":"The C curve means the magnetic trip operates at 5 to 10 times the rated current, so for a 32 A breaker it trips magnetically between 160 A and 320 A. This suits moderate inrush loads like small motors, transformers, and fluorescent lighting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N4P32CGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N4P32CGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}