{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N4P50CGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N4P50CGN","canonicalUrl":"https://aoctrl.com/schneider/A9N4P50CGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N4P50CGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit breaker, 4-pole, 50 A, C curve, 10 kA breaking capacity to IS/IEC 60898-1, clip-on 35 mm DIN rail mount.","salesMarkdown":"The Schneider Electric A9N4P50CGN is an Acti9 xC60 miniature circuit breaker rated 50 A with a C curve (magnetic trip between 5 and 10 times In) and a breaking capacity of 10 kA Icn at both 240 V and 415 V AC per IS/IEC 60898-1. For a 50 A 4-pole breaker, the 10 kA rating means it can safely interrupt a fault current up to that level on a 415 V three-phase distribution board — typical for commercial or light industrial sub-mains where the prospective short-circuit current is under 10 kA. Depth is 77.5 mm, height 85 mm — confirm the gland plate clearance if the panel is shallow. Designed and tested to IS/IEC 60898-1, the Indian-standard adoption of the IEC 60898-1 for MCBs in household and similar installations. The limitation class is 3 per IS/IEC 60898-1, meaning it limits let-through energy to a defined level under short-circuit conditions. Tropicalisation level 2 per IEC 60068-1 indicates the breaker is treated for damp heat — relevant for coastal or high-humidity installations. Overvoltage category IV confirms it can be used at the main distribution board, not just downstream sub-panels.","metaTitle":"Schneider Electric A9N4P50CGN Acti9 xC60 MCB, 50 A, 4P, C Cu","metaDescription":"Schneider Electric A9N4P50CGN Acti9 xC60 miniature circuit breaker, 50 A rated current, 4 poles, C curve, 10 kA breaking capacity to IS/IEC 60898-1. Active production, sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m","Device application":"Distribution","[In] rated current":"50 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Biconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid","IP degree of protection":"IP20","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N4P50CGN/miniature-circuit-breaker-mcb-acti9-xc60-4p-50a-c-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N4P50CGN/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9N4P50CGN?","answer":"The A9N4P50CGN is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."},{"question":"What is the breaking capacity of the A9N4P50CGN?","answer":"The breaking capacity is 10 kA Icn at both 240 V AC and 415 V AC, 50/60 Hz, conforming to IS/IEC 60898-1."},{"question":"What is the closest alternative to the A9N4P50CGN in the same family?","answer":"Within the Acti9 xC60 range, the closest peer is the 4-pole 63 A C-curve variant (different rated current). For a 50 A 4-pole, the A9N4P50CGN is the current offering; no pin-compatible alternative exists at the same rating within the same family — the rating is the selection parameter."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N4P50CGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N4P50CGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}