{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N61514","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N61514","canonicalUrl":"https://aoctrl.com/schneider/A9N61514","factsUrl":"https://aoctrl.com/api/mcp/products/A9N61514","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 C60H-DC, A9N61514, miniature circuit-breaker, 1P, 30 A, C-curve, 10 kA Icu at 220 V DC, thermal-magnetic, DC network.","salesMarkdown":"## DC-rated miniature circuit-breaker for distribution panels The Schneider Electric A9N61514 is a 1-pole Acti9 C60H-DC miniature circuit-breaker rated 30 A at 25 °C, with a C-curve trip characteristic and thermal-magnetic technology. The breaker occupies 2 x 9 mm pitches (18 mm) of panel width. Breaking capacity is specified per IEC/EN 60947-2: 10 kA Icu at 220 V DC, 6 kA Icu at 250 V DC, and 20 kA Icu at 110 V DC. The service breaking capacity Ics is 75 % of Icu at each voltage level — 7.5 kA at 220 V DC, 4.5 kA at 250 V DC, and 15 kA at 110 V DC. That means after clearing a fault at the Ics level, the breaker remains functional for continued service, not just a one-shot trip. Rated operational voltage is 250 V DC, with an insulation voltage of 500 V DC and impulse withstand of 6 kV. Overvoltage category IV and pollution degree 3 suit it for main distribution panel environments where transient overvoltages are expected. ## What the C-curve and DC ratings mean for your circuit The C-curve (trip threshold 5 to 10 times In) is standard for inductive or moderate inrush loads — think DC motor drives, solenoid banks, or control transformers where the start-up current exceeds the steady-state rating but stays within a predictable band. For a 30 A breaker, magnetic trip occurs between 150 A and 300 A. DC arc extinction is fundamentally different from AC — there is no natural zero-crossing to quench the arc. The C60H-DC's arc chamber and contact gap are engineered for DC interruption, certified to EN/IEC 60947-2. For a 48 V DC telecom bus or a 110 V DC control panel, the 20 kA Icu provides substantial headroom. Suitability for isolation per IEC 60947-2 is confirmed — the contact position indicator and padlockable toggle (lockable in the O position) provide visible break and lockout/tagout capability. This matters for a DC panel where an upstream isolator may not be present. ## Environmental and installation limits Tropicalisation class 2 per IEC 60068-2 indicates the breaker is treated for resistance to heat and humidity — relevant for panels in non-conditioned spaces or near process heat. Altitude derating applies above 2000 m. Terminal torque spec is 2.5 N·m for the power circuit, top or bottom. The spring-cage terminals accept standard copper conductors; strip length and ferrule sizing per the manufacturer's installation guide. The 35 mm DIN rail mount is fixed — no clip-on or plug-in base. Mechanical endurance is rated at 20,000 cycles; electrical endurance at 3,000 cycles with a load time constant L/R = 2 ms. That electrical figure is the limiting factor for frequent switching applications — if the breaker cycles daily under load, plan for replacement well before the mechanical life is reached.","metaTitle":"Schneider Electric A9N61514 Acti9 C60H-DC MCB, 30 A, 1P, C-C","metaDescription":"Schneider Electric A9N61514 Acti9 C60H-DC miniature circuit-breaker, 30 A, 1-pole, C-curve, 10 kA at 220 V DC. Current lifecycle stage, sourced to order. EN/IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White","Voltage":"250 V DC","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to EN 60947-2 3 conforming to IEC 60947-2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V DC conforming to IEC 60947-2 500 V DC conforming to EN 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Electrical Life Cycles":"3000 cycles L/R = 2 ms","Mechanical Life Cycles":"20000 cycles","Main Product Or Component Type":"Miniature circuit-breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$35.90","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bb7bcb924eae0b330f7b0fa8fdfe0f35.pdf","sourceUrl":"https://www.se.com/nz/en/product/A9N61514/miniature-circuit-breaker-mcb-acti9-c60hdc-1p-30a-c-curve-6ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N61514/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N61514","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N61514 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}