{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9P44710","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9P44710","canonicalUrl":"https://aoctrl.com/schneider/A9P44710","factsUrl":"https://aoctrl.com/api/mcp/products/A9P44710","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC40N, miniature circuit breaker, 10 A, 3P + N, B curve, 10 kA Icu at 400 V AC, clip-on DIN rail mount, IP20.","salesMarkdown":"It is a 3P+N device rated at 10 A with a B tripping curve. The breaking capacity is 10 kA Icu at 400 V AC per IEC 60947-2, and 6000 A Icn at 400 V AC per IEC 60898-1. That dual rating means this breaker is certified for both the industrial standard (60947-2) and the domestic/light-commercial standard (60898-1), giving it a wider acceptance in panel specs that call for either. The limitation class is 3 per EN/IEC 60898-1, which means it limits let-through energy enough to protect downstream equipment in most fault scenarios. The thermal-magnetic trip unit handles the overload (thermal) and short-circuit (magnetic) protection. The magnetic trip is factory-set to 4 x In ±20% per IEC 60947-2, and the B-curve window of 3 to 5 x In per IEC 60898-1. Clip-on mounting onto a DIN rail. The 3P+N breaker occupies 6 module pitches of 9 mm each, so 54 mm total width. Strip length is 14 mm. The toggle control provides ON/OFF indication plus a trip indicator. Contact position indicator is present, so you can visually confirm the state of the contacts. The breaker is certified to EN/IEC 60898-1 and EN/IEC 60947-2. The dual certification is a practical advantage: it satisfies both the domestic MCB standard and the industrial standard for circuit-breakers, so the same part can be specified in a panel that must meet either or both. The suitability for isolation (IEC 60947-2) adds another layer of utility — the breaker can serve as a disconnecting means without requiring a separate isolator. Operating altitude is rated to 2000 m. Relative humidity tolerance is 95% at 55 °C. The electrical and mechanical durability are both rated at 20,000 cycles. Earth-leakage protection is handled by a separate block (not integrated), so if you need RCD protection, you pair this with a compatible Acti9 Vigi module.","metaTitle":"Schneider Electric A9P44710 Acti9 iC40N MCB, 10A, 3P+N, B Cu","metaDescription":"Schneider Electric A9P44710 Acti9 iC40N miniature circuit breaker. 10A rated current, 3P+N, B curve, 10 kA breaking capacity at 400 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1 EN/IEC 60947-2","Curve code":"B","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC40","Mounting mode":"Clip-on","Quality labels":"IMQ OVE","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC40N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"10 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In conforming to EN/IEC 60898-1 4 x In +/- 20 % conforming to EN/IEC 60947-2","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$114.21","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9P44710/miniature-circuit-breaker-mcb-acti9-ic40n-3p+n-10a-b-curve-6000a-iec-en-608981-10ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9P44710/alternatives.json"},"ai":{"faq":[{"question":"What range does the A9P44710 belong to?","answer":"It belongs to the Acti9 range, specifically the iC40N series of miniature circuit-breakers. Acti9 is Schneider Electric's modular protection range for residential and commercial distribution."},{"question":"What compliance documentation does Schneider provide for the A9P44710?","answer":"The breaker is certified to EN/IEC 60898-1 and EN/IEC 60947-2. It carries IMQ and OVE quality labels. The IP ratings are IP20 (body) and IP40 (modular enclosure) per IEC 60529. Standard RoHS and REACH declarations are available from Schneider Electric for the Acti9 range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9P44710","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9P44710 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}