{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9P54716","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9P54716","canonicalUrl":"https://aoctrl.com/schneider/A9P54716","factsUrl":"https://aoctrl.com/api/mcp/products/A9P54716","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC40N miniature circuit breaker, A9P54716, 16 A rated current, C-curve, 3P+N, 10 kA Icu at 400 V AC, dual-rated EN/IEC 60898-1 and 60947-2.","salesMarkdown":"The Schneider Electric A9P54716 is a 16 A C-curve miniature circuit breaker from the Acti9 iC40N series, configured as 3P+N. It carries a dual rating to EN/IEC 60898-1 (6 kA Icn at 400 V AC) and EN/IEC 60947-2 (10 kA Icu at 400 V AC), which means it can be specified for either domestic-distribution or industrial-panel applications where the higher breaking capacity is needed for fault coordination. The thermal-magnetic trip unit provides C-curve protection (magnetic trip at 5–10× In per 60898-1, 8× In ±20% per 60947-2), suited for mixed resistive and moderate inductive loads like lighting circuits, small motor starters, and general-purpose branch protection. ## Breaking capacity and dual-standard rating The 6 kA Icn under EN/IEC 60898-1 is the domestic/commercial rating, sufficient for most final distribution circuits. Having both on one nameplate means the same part can be stocked for both job types, simplifying BOM management for an integrator who works across residential and light-industrial sites. Clip-on mounting to DIN rail (35 mm symmetrical rail per EN 60715) with a 54 mm width (6 x 9 mm pitches). The 3P+N configuration places the neutral pole on the left, with the toggle control providing ON/OFF and trip-indicator local signalling. Tunnel-type terminals accept 1–16 mm² rigid or 1–10 mm² flexible conductors; tightening torque is 2 N·m. Quality labels include OVE, IMQ, and AENOR. Earth-leakage protection requires a separate Vigi block — not integrated.","metaTitle":"Schneider A9P54716 Acti9 iC40N MCB, 16 A C-Curve 3P+N 10 kA","metaDescription":"Schneider A9P54716 Acti9 iC40N miniature circuit breaker, 16 A rated current, C-curve, 3P+N, 10 kA Icu at 400 V AC. Dual-rated to EN/IEC 60898-1 and 60947-2. Current lifecycle stag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1 EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC40","Mounting mode":"Clip-on","Quality labels":"OVE IMQ AENOR","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC40N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"16 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In conforming to EN/IEC 60898-1 8 x In +/- 20 % conforming to EN/IEC 60947-2","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$112.00","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/il/en/product/A9P54716/miniature-circuitbreaker-acti9-ic40n-3p+n-16-a-c-curve-6000-a-iec-608981-10-ka-iec-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9P54716/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9P54716 and what is the lead time?","answer":"The A9P54716 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of the A9P54716?","answer":"The A9P54716 has a dual breaking capacity rating: 10 kA Icu at 400 V AC per EN/IEC 60947-2 for industrial use, and 6 kA Icn at 400 V AC per EN/IEC 60898-1 for domestic/commercial circuits."},{"question":"What standards does the A9P54716 comply with?","answer":"The A9P54716 is dual-rated to EN/IEC 60898-1 and EN/IEC 60947-2, covering both domestic and industrial application standards. It also carries OVE, IMQ, and AENOR quality labels."},{"question":"What is the A9P54716's depth and width for panel layout?","answer":"The A9P54716 has a depth of 74 mm and a width of 54 mm (6 x 9 mm pitches), fitting standard DIN-rail enclosures with 3P+N spacing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9P54716","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9P54716 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}