{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9P54732","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9P54732","canonicalUrl":"https://aoctrl.com/schneider/A9P54732","factsUrl":"https://aoctrl.com/api/mcp/products/A9P54732","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC40N miniature circuit breaker, A9P54732, 32 A, C curve, 3P+N, 10 kA Icu at 400 V AC, thermal-magnetic trip, DIN-rail clip-on.","salesMarkdown":"The Schneider Electric A9P54732 is an Acti9 iC40N miniature circuit breaker rated 32 A with a C curve, 3P+N poles, and a breaking capacity of 10 kA Icu at 400 V AC (EN/IEC 60947-2) and 6 kA Icn at 400 V AC (EN/IEC 60898-1). It uses a thermal-magnetic trip unit and clips onto a DIN rail. The C curve (magnetic trip 5–10 × In) means this breaker handles moderate inrush — typical for motor starters, small transformers, and lighting banks — without nuisance tripping on start-up. The 32 A rating suits branch circuits feeding a mix of resistive and light inductive loads up to that continuous current. The dual-standard rating (EN/IEC 60898-1 for household and similar installations, EN/IEC 60947-2 for industrial distribution) gives you flexibility: it can serve in a final sub-distribution board or in an industrial panel where the higher Icu (10 kA) matters for fault clearance coordination. The 3P+N configuration protects three phases; the neutral is switched but not protected. ## Panel integration Top and bottom tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; tighten to 2 N·m. Strip length 14 mm.","metaTitle":"Schneider Electric A9P54732 Acti9 iC40N MCB, 32 A, C Curve,","metaDescription":"Schneider Electric A9P54732 Acti9 iC40N miniature circuit breaker, 32 A rated current, C curve, 3P+N, 10 kA Icu at 400 V AC. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1 EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC40","Mounting mode":"Clip-on","Quality labels":"OVE AENOR IMQ","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC40N","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"32 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In conforming to EN/IEC 60898-1 8 x In +/- 20 % conforming to EN/IEC 60947-2","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 5 kA 50 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$141.91","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9P54732/miniature-circuit-breaker-mcb-acti9-ic40n-3p+n-32a-c-curve-6000a-iec-en-608981-10ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9P54732/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9P54732?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"What is A9P54732's listed depth?","answer":"The A9P54732 has a depth of 74 mm."},{"question":"What is A9P54732's listed range?","answer":"The A9P54732 belongs to the Acti9 range, specifically the iC40N series of miniature circuit breakers."},{"question":"What compliance documentation does this brand provide for A9P54732?","answer":"The A9P54732 carries quality labels OVE, AENOR, and IMQ, and complies with EN/IEC 60898-1 and EN/IEC 60947-2. It is suitable for isolation per EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9P54732","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9P54732 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}