{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9P55716","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9P55716","canonicalUrl":"https://aoctrl.com/schneider/A9P55716","factsUrl":"https://aoctrl.com/api/mcp/products/A9P55716","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC40H, A9P55716, miniature circuit breaker, 16 A, C-curve, 3P+N, 10 kA Icn at 400 V AC, DIN-rail clip-on.","salesMarkdown":"The Schneider Electric A9P55716 is an Acti9 iC40H miniature circuit breaker (MCB) rated 16 A with a C-curve, 3P+N poles, and a 10 kA breaking capacity at 400 V AC per EN/IEC 60898-1. The 3P+N configuration protects three phases and switches the neutral, common in three-phase distribution boards where the neutral is not overload-protected but is switched with the phases. The 54 mm width occupies 6 × 9 mm pitches. Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; strip length 14 mm, torque to 2 N·m. IP20 finger-safe on the front, IP40 inside the modular enclosure — fine for a dry indoor panel, not for washdown.","metaTitle":"Schneider Electric A9P55716 Acti9 iC40H MCB, C-Curve 16 A 3P","metaDescription":"Schneider Electric A9P55716 Acti9 iC40H miniature circuit breaker, 16 A rated current, C-curve, 3P+N, 10 kA breaking capacity at 400 V AC. Active production, sourced to order again","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC40","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Breaking capacity":"10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC40H","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"16 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In conforming to EN/IEC 60898-1","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/il/en/product/A9P55716/miniature-circuitbreaker-acti9-ic40h-3p+n-16-a-c-curve-10000-a-iec-608981-iec-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9P55716/alternatives.json"},"ai":{"faq":[{"question":"What is A9P55716's breaking capacity?","answer":"The A9P55716 has a 10 kA Icn breaking capacity at 400 V AC 50/60 Hz per EN/IEC 60898-1."},{"question":"Where can I buy A9P55716?","answer":"The A9P55716 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Schneider provide for A9P55716?","answer":"The A9P55716 is certified to EN/IEC 60898-1 and carries IP20/IP40 ratings per IEC 60529. Standard Schneider documentation includes the declaration of conformity and test reports for the listed standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9P55716","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9P55716 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}