{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9P62732","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9P62732","canonicalUrl":"https://aoctrl.com/schneider/A9P62732","factsUrl":"https://aoctrl.com/api/mcp/products/A9P62732","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC40, miniature circuit breaker, 32 A, D curve, 3P+N, 4.5 kA Icn at 400 V AC, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9P62732 is an Acti9 iC40 miniature circuit breaker rated 32 A with a D tripping curve, 3 poles protected plus switched neutral (3P+N). It clips onto a standard DIN rail — the 54 mm width occupies 6 module pitches at 9 mm each, so plan for that slot in your enclosure layout. Breaking capacity is 4.5 kA Icn at 400 V AC per EN/IEC 60898-1 for the residential/commercial rating, and 6 kA Icu at 400 V AC per EN/IEC 60947-2 for the industrial rating. The D curve's magnetic trip threshold is 10–14 × In per IEC 60898-1, or 12 × In ±20 % per IEC 60947-2. Clip-on mounting to DIN rail, neutral on the left. Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible copper; tighten to 2 N·m. Strip 14 mm for top or bottom connection. IP20 finger-safe on the front face; IP40 inside the modular enclosure. Thermal-magnetic trip unit. Padlocking provision on the toggle for lockout/tagout.","metaTitle":"Schneider Electric A9P62732 Acti9 iC40 MCB, 32 A, D Curve, 3","metaDescription":"Schneider Electric A9P62732 Acti9 iC40 miniature circuit breaker, 32 A rated current, D curve, 3P+N, 4.5 kA breaking capacity per IEC 60898-1. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"74 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1 EN/IEC 60947-2","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC40","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"ON/OFF indication Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2","Device short name":"iC40","Network frequency":"50/60 Hz","Poles description":"3P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"32 A","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"10...14 x In conforming to EN/IEC 60898-1 12 x In +/- 20 % conforming to EN/IEC 60947-2","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"4500 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 4.5 kA 75 % x Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9P62732/miniature-circuitbreaker-acti9-ic40-3p+n-32-a-d-curve-4500-a-iec-608981-6-ka-iec-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9P62732/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9P62732?","answer":"4.5 kA Icn at 400 V AC per EN/IEC 60898-1 and 6 kA Icu at 400 V AC per EN/IEC 60947-2. The higher figure applies under the industrial standard."},{"question":"Where can I buy A9P62732 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does this brand provide for A9P62732?","answer":"The breaker is certified to EN/IEC 60898-1 and EN/IEC 60947-2. Pollution degree 3 per IEC 60947-2. The Acti9 range typically carries CE, UKCA, and EAC markings; specific declarations are available from Schneider Electric on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9P62732","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9P62732 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}