{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Q01240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Q01240","canonicalUrl":"https://aoctrl.com/schneider/A9Q01240","factsUrl":"https://aoctrl.com/api/mcp/products/A9Q01240","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 40 A, 30 mA, Type AC, clip-on DIN rail.","salesMarkdown":"The 73.5 mm depth fits standard distribution boards; tunnel terminals accept up to 35 mm² rigid cable at the bottom, with a tightening torque of 3.5 N.m. The 30 mA sensitivity is the standard threshold for personal protection against indirect contact — it trips within the IEC 61009-1 time curve before a fault current reaches a dangerous level for a human body. Rated operational voltage is 110...130 V AC, 50/60 Hz — sized for single-phase line-to-neutral supplies in that band. Insulation voltage is rated 500 V AC, impulse withstand 6 kV, pollution degree 3, so it holds up in industrial panels where transient spikes and conductive dust are present. The voltage-independent trip mechanism means the RCD does not need a separate power supply or neutral reference to open on a fault — it uses the fault energy itself, so it remains functional even if the neutral is lost upstream. This is an outgoer device — it sits on the load side of the iC60 MCB, plugging in via the integrated electrical connection. The clip-on DIN rail mount and 36 mm width (4 modules) mean it takes up four standard 9 mm pitches in a distribution board. Bottom connection accepts comb busbars for daisy-chaining multiple outgoing circuits.","metaTitle":"Schneider Electric A9Q01240 Vigi iC60 RCD, 2P 40A 30mA AC ty","metaDescription":"Schneider Electric A9Q01240 Vigi iC60 add-on residual current device, 2P, 40 A, 30 mA sensitivity, Type AC, for DIN rail mounting. Active lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"36 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"4","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m bottom","[In] rated current":"40 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"Plug in","Earth leakage protection type":"Type AC","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"110...130 V AC 50/60 Hz conforming to EN/IEC 61009-1 110...130 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9b30593009e1fbfcbf132821761cc495.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9Q01240/vigi-ic60-earth-leakage-addon-block-2p-40a-30ma-ac-type/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Q01240/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9Q01240 and how is it quoted for volume purchases?","answer":"The A9Q01240 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is A9Q01240's listed depth?","answer":"The A9Q01240 has a depth of 73.5 mm."},{"question":"What is A9Q01240's listed range?","answer":"The A9Q01240 belongs to the Schneider Electric Acti9 range, specifically the Vigi iC60 series."},{"question":"What compliance documentation does this brand provide for A9Q01240?","answer":"The A9Q01240 complies with EN/IEC 61009-1 and EN/IEC 61009-2-1 standards. It carries IP20 and IP40 ingress protection ratings per IEC 60529, and pollution degree 3 per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Q01240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Q01240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}