{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Q31340","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Q31340","canonicalUrl":"https://aoctrl.com/schneider/A9Q31340","factsUrl":"https://aoctrl.com/api/mcp/products/A9Q31340","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 40 A, 30 mA, Type A-SI, instantaneous, 400…415 V AC, obsolete.","salesMarkdown":"The Schneider Electric A9Q31340 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range — a voltage-independent, instantaneous-trip module that plugs into the side of an iC60 MCB to add earth-leakage protection. It is rated 40 A, 30 mA sensitivity, Type A-SI (Super Immunised), meaning it handles pulsed DC fault currents and resists nuisance tripping from high-frequency harmonics common on VFD-fed or UPS-backed circuits. Three-pole (3P) construction clips onto DIN rail, occupying 7 modules of 9 mm pitch (63 mm wide). ## Lifecycle reality — obsolete, but available The A9Q31340 is marked obsolete by Schneider Electric. If you are holding a last-time-buy window or managing a legacy panel, this is the part to source now; there is no direct drop-in replacement from the manufacturer. Rated operational voltage is 400…415 V AC, 50/60 Hz, per EN/IEC 61009-1 and -2-1 — the standard for residual-current-operated circuit-breakers with integral overcurrent protection. Type A-SI (Super Immunised) means it withstands 8/20 µs impulse currents up to 3000 A without tripping, so it holds steady on circuits with surge suppressors or switching transients. Instantaneous trip time means no intentional delay — it clears a ground fault as fast as the coil can move. Clip-on mounting to DIN rail, 63 mm wide (7 x 9 mm pitches). Depth is 73.5 mm, height 91 mm. IP20 on the body, IP40 inside a modular enclosure. Bottom comb busbar compatible. The trip indicator gives local visual confirmation of a residual-current event — useful for panel troubleshooting.","metaTitle":"A9Q31340 Acti9 Vigi iC60 3P 40A 30mA A-SI RCD, obsolete","metaDescription":"Schneider Electric A9Q31340 Acti9 Vigi iC60 add-on RCD, 3P 40A 30mA Type A-SI, 400-415V AC. Obsolete — sourced to order against RFQ via independent distribution.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"73.5 mm","Width":"63 mm","Height":"91 mm","Voltage":"400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e409735edf925e4d54660638fa1320bf.pdf","sourceUrl":"https://www.se.com/id/en/product/A9Q31340/addon-residual-current-device-acti9-vigi-ic60-3p-40a-asi-type-instantaneous-30ma-400-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Q31340/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Q31340","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Q31340 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}