{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Q41440","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Q41440","canonicalUrl":"https://aoctrl.com/schneider/A9Q41440","factsUrl":"https://aoctrl.com/api/mcp/products/A9Q41440","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on RCD, 4P, 40A, AC type, 30mA sensitivity, 400-415 VAC, instantaneous, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9Q41440 is an add-on residual current device from the Acti9 Vigi iC60 range, rated 40 A with 30 mA earth-leakage sensitivity, AC type, instantaneous trip, for 400-415 V AC 50/60 Hz networks. It clips onto a compatible Acti9 iC60 MCB via the plug-in connection, adding earth-fault protection without extra wiring or panel space — the combined unit occupies the same 63 mm width (7 x 9 mm pitches) as a standard 4P MCB. The 30 mA sensitivity means it trips on ground faults as low as 30 mA, which is the standard threshold for personnel protection under IEC 61009-1 — it clears a fault before leakage reaches a dangerous level for the operator. Type AC detection covers sinusoidal AC residual currents only; if the downstream load includes rectifiers, VFDs, or switched-mode supplies that generate pulsed or DC fault current, Type A or Type B would be needed instead. The 40 A rating matches the MCB it mounts to, so the RCD and overcurrent device share the same current-carrying capacity — no derating mismatch on the outgoing circuit. Voltage-independent tripping means the RCD detects and interrupts a ground fault even if the phase voltage collapses or the neutral is lost — the trip mechanism draws its energy from the fault current itself, not from the supply. That matters for safety: a broken neutral won't leave the RCD blind. Clip-on mounting to DIN rail — snaps onto the rail alongside the iC60 MCB, no tools needed for the mechanical fit. The plug-in electrical connection between RCD and MCB eliminates interconnecting wires; the assembly behaves as a single 4P device. Tunnel-type terminals on the bottom accept 1-35 mm² rigid or 1-25 mm² flexible cable, with a tightening torque of 3.5 N·m and a strip length of 14 mm. The bottom comb busbar compatibility allows a common neutral or phase busbar to feed multiple RCD/MCB pairs in a distribution board.","metaTitle":"Schneider Electric A9Q41440 Acti9 Vigi iC60 4P 40A 30mA RCD","metaDescription":"Schneider Electric A9Q41440 Acti9 Vigi iC60 add-on RCD, 4P, 40A, 30mA AC type, 400-415V. Active production. Sourced to order. RFQ for price and availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"73.5 mm","Width":"63 mm","Height":"91 mm","Voltage":"400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/99133a0e4b3ec8d50d5cb39cc2fecd0a.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9Q41440/addon-residual-current-device-acti9-vigi-ic60-4p-40a-ac-type-instantaneous-30ma-400-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Q41440/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Q41440","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Q41440 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}