{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Q44340","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Q44340","canonicalUrl":"https://aoctrl.com/schneider/A9Q44340","factsUrl":"https://aoctrl.com/api/mcp/products/A9Q44340","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 series, Vigi iC60 add-on residual current device, 3P, 40 A, 300 mA, Type AC, instantaneous, 230...415 V AC.","salesMarkdown":"The A9Q44340 is a voltage-independent add-on residual current device (RCD) from the Acti9 Vigi iC60 family — clips onto the outgoing side of a compatible iC60 MCB to add earth-leakage protection without extra wiring. The 40 A rated current and 300 mA sensitivity mean it's sized for sub-distribution or feeder circuits where the load draws up to 40 A and you need a higher trip threshold to avoid nuisance tripping from leakage in long cable runs or industrial loads. Type AC detection handles sinusoidal AC residual currents only — fine for general lighting, socket outlets, and resistive loads, but not for pulsed or DC-ripple waveforms from VFDs, UPS, or EV chargers. The 230...415 V AC operational voltage covers single-phase and three-phase networks within that range. Voltage-independent tripping means the RCD disconnects even if the phase voltage collapses — a safety advantage for circuits where loss of neutral could otherwise mask a fault. Clip-on mounting on standard DIN rail — snaps directly onto the rail beside or downstream of the iC60 MCB. The plug-in electrical connection to the MCB means no additional phase wiring; the RCD draws its supply through the MCB's outgoing terminals. Occupies 7 modules of 9 mm pitch, so 63 mm total width. Depth of 73.5 mm fits standard distribution boards and enclosures; verify gland-plate clearance if the board is shallow. IP20 finger-safe for enclosed panels; IP40 when installed in a modular enclosure. Tightening torque 3.5 N.m.","metaTitle":"Schneider Electric A9Q44340 Acti9 Vigi iC60 RCD, 3P, 40A, 30","metaDescription":"Schneider Electric A9Q44340 Acti9 Vigi iC60 add-on RCD, 3P, 40A, 300 mA, Type AC, instantaneous, 230-415 VAC. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"73.5 mm","Width":"63 mm","Height":"91 mm","Voltage":"230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c7844cfecc0638515f8e4bb024ff6654.pdf","sourceUrl":"https://www.se.com/id/en/product/A9Q44340/addon-residual-current-device-acti9-vigi-ic60-3p-40a-ac-type-instantaneous-300ma-230-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Q44340/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Q44340","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Q44340 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}