{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Q61240","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Q61240","canonicalUrl":"https://aoctrl.com/schneider/A9Q61240","factsUrl":"https://aoctrl.com/api/mcp/products/A9Q61240","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 40 A, 30 mA, Type A-SI, instantaneous, 230-240 V AC, clip-on DIN rail.","salesMarkdown":"Rated 40 A with 30 mA earth-leakage sensitivity, it trips instantaneously and carries Type A-SI (Super Immunised) classification, meaning it handles pulsed DC fault currents and resists nuisance tripping from high-frequency harmonics or transient surges common on modern electronic loads. The 40 A [In] rating matches the upstream MCB's thermal-magnetic curve — this RCD does not provide overcurrent protection itself; it monitors leakage only. The 30 mA sensitivity is the standard threshold for personnel protection (shock risk) per IEC 60364, while the instantaneous trip (no intentional delay) ensures fast disconnection on earth faults. Type A-SI (Super Immunised) is the deciding factor for installations with variable-speed drives, UPS systems, or LED lighting — loads that generate smooth DC fault currents or high-frequency leakage that would desensitise or falsely trip a standard Type A or AC device. The 8/20 µs impulse withstand rating of 3000 A confirms it survives surge events without welding the sensing coil. The insulation voltage is 500 V AC, and impulse withstand is 6 kV — figures that align with IEC 60947-2 for coordination in standard distribution panels. Clip-on mounting to DIN rail, 36 mm width (2 modules at 9 mm pitch each), 73.5 mm depth. Plugs directly into the right-side busbar of an iC60 MCB via the tunnel-type terminals — no additional wiring needed for the phase connection. Bottom terminals accept 1 to 35 mm² rigid or 1 to 25 mm² flexible cable; tighten to 3.5 N·m. Strip length 14 mm. The trip indicator gives local visual confirmation of a residual-current trip, aiding fault diagnosis without unclipping the module.","metaTitle":"Schneider Electric A9Q61240 Acti9 Vigi iC60 2P 40A 30mA A-SI","metaDescription":"Schneider Electric A9Q61240 Acti9 Vigi iC60 add-on RCD, 2P, 40A, 30mA, Type A-SI, instantaneous, 230-240V AC. Active production. DIN rail mount. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"36 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"4","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m bottom","[In] rated current":"40 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"Plug in","Earth leakage protection type":"Type A-SI (Super Immunised)","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"230...240 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/43299cf4d10ba9dd7e4ec7514af1e613.pdf","sourceUrl":"https://www.se.com/id/en/product/A9Q61240/addon-residual-current-device-acti9-vigi-ic60-2p-40a-asi-type-instantaneous-30ma-230-240vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Q61240/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9Q61240 and how do I get a price?","answer":"The A9Q61240 is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing."},{"question":"What is A9Q61240's listed depth?","answer":"The A9Q61240 has a depth of 73.5 mm."},{"question":"What is A9Q61240's listed range?","answer":"The A9Q61240 belongs to the Schneider Electric Acti9 range, specifically the Vigi iC60 family of add-on residual current devices."},{"question":"What compliance documentation does this brand provide for A9Q61240?","answer":"The A9Q61240 is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. It carries IP20/IP40 ingress protection ratings per IEC 60529 and pollution degree 3 per IEC 60947-2. The manufacturer typically provides RoHS and REACH declarations on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Q61240","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Q61240 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}