{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Q61325","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Q61325","canonicalUrl":"https://aoctrl.com/schneider/A9Q61325","factsUrl":"https://aoctrl.com/api/mcp/products/A9Q61325","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, 3P, 25 A, 30 mA, Type A-SI, 400…415 V AC, instantaneous, obsolete.","salesMarkdown":"The Schneider Electric A9Q61325 is an Acti9 Vigi iC60 add-on residual current device (RCD) — 3-pole, rated 25 A, with 30 mA earth-leakage sensitivity, Type A-SI (Super Immunised), for 400…415 V AC networks at 50/60 Hz. The 30 mA sensitivity catches earth faults that could otherwise go undetected by an MCB alone — standard for personal protection against indirect contact. Voltage-independent tripping means the RCD operates even if the phase voltage collapses — no auxiliary supply needed. Instantaneous time delay means it clears faults as fast as the internal solenoid allows, which is the default for most distribution boards unless you need selectivity with a delayed upstream RCD. Rated operational voltage is 400…415 V AC — standard three-phase line-to-line for European low-voltage networks. This is an outgoer device — it sits downstream of the main switch or incoming breaker, protecting a final subcircuit.","metaTitle":"Schneider Electric A9Q61325 Acti9 Vigi iC60, 3P, 25A, 30mA,","metaDescription":"Schneider Electric A9Q61325 Acti9 Vigi iC60 add-on RCD, 3P, 25A, 30mA, Type A-SI, 400-415VAC. Obsolete — sourced to order against an RFQ. EN/IEC 61009-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"73.5 mm","Width":"54 mm","Height":"91 mm","Voltage":"400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4b36bdb0e277090da34a4fd3e078a67b.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9Q61325/addon-residual-current-device-acti9-vigi-ic60-3p-25a-asi-type-instantaneous-30ma-400-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Q61325/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Q61325","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Q61325 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}