{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Q61340","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Q61340","canonicalUrl":"https://aoctrl.com/schneider/A9Q61340","factsUrl":"https://aoctrl.com/api/mcp/products/A9Q61340","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60, add-on residual current device, 3P, 40A, 30 mA, Type A-SI (Super Immunised), instantaneous, 400...415 V AC, 50/60 Hz.","salesMarkdown":"The Schneider Electric A9Q61340 is a 3-pole add-on residual current device (RCD) from the Acti9 Vigi iC60 series, rated 40 A with 30 mA earth-leakage sensitivity. It clips onto the side of an Acti9 iC60 miniature circuit breaker (MCB) via the plug-in electrical connection, making it a combined RCBO assembly in a single DIN-rail footprint. The 63 mm width and 73.5 mm depth fit standard 9 mm pitch enclosures — it occupies 7 pitches. This is an outgoer device, meaning it sits downstream of the main breaker to protect a specific final circuit. ## Why the Type A-SI and 30 mA matter The Type A-SI (Super Immunised) earth-leakage protection is voltage-independent — it trips on residual current alone, without needing a separate power supply. The \"SI\" suffix means it's hardened against nuisance tripping from high-frequency leakage and transient surges common on drives, inverters, and switching power supplies. In a mill environment with VFDs and contactor coils, standard Type A RCDs can false-trip on the capacitive leakage from drive input filters; the A-SI holds through that. The 30 mA sensitivity catches direct-contact faults (hand-to-ground currents above the let-go threshold) while the instantaneous time delay clears the fault in under 40 ms — no intentional delay for selectivity. The 8/20 µs impulse withstand of 3000 A means it survives lightning-induced or switching surges without damage. Mounting is clip-on to a DIN rail, with the plug-in connection to the adjacent iC60 MCB. The tunnel-type terminals on the bottom accept 1 to 35 mm² rigid cable (or 1 to 25 mm² flexible, with or without ferrule). The bottom busbar and distribution block compatibility means you can feed the line side via a comb busbar across multiple devices. The IP20 rating covers the device body; in a modular enclosure it reaches IP40 — sufficient for enclosed distribution boards but not for washdown locations.","metaTitle":"Schneider Electric A9Q61340 Acti9 Vigi iC60, 40A, 30mA, 3P","metaDescription":"Schneider Electric A9Q61340 Acti9 Vigi iC60 add-on RCD. 3P, 40A, 30mA Type A-SI, 400-415V AC. Active production, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"63 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"7","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"3.5 N.m bottom","[In] rated current":"40 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...25 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"Plug in","Earth leakage protection type":"Type A-SI (Super Immunised)","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4196b3cafd04b1f1e053c9b6118e8cb9.pdf","sourceUrl":"https://www.se.com/id/en/product/A9Q61340/addon-residual-current-device-acti9-vigi-ic60-3p-40a-asi-type-instantaneous-30ma-400-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Q61340/alternatives.json"},"ai":{"faq":[{"question":"Is A9Q61340 available via RFQ confirmation and what is the lead time?","answer":"We source the A9Q61340 to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to A9Q61340?","answer":"There is no pin-compatible alternative in the Acti9 range — the Vigi iC60 is the only add-on RCD that mates mechanically and electrically with the iC60 MCB."},{"question":"What is A9Q61340's listed depth (73.5 mm) on this component line?","answer":"The A9Q61340 has a depth of 73.5 mm, a width of 63 mm, and a height of 91 mm, occupying 7 standard 9 mm pitches on a DIN rail."},{"question":"What compliance documentation does this brand provide for A9Q61340?","answer":"The A9Q61340 is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1 for residual current circuit breakers, with a rated impulse withstand voltage of 6 kV per IEC 60947-2 and pollution degree 3 per the same standard. The IP20/IP40 ratings conform to IEC 60529."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Q61340","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Q61340 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}