{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9Q61425","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9Q61425","canonicalUrl":"https://aoctrl.com/schneider/A9Q61425","factsUrl":"https://aoctrl.com/api/mcp/products/A9Q61425","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9Q61425, 4P, 25 A, 30 mA, Type A-SI, 400...415 V AC.","salesMarkdown":"The Schneider Electric A9Q61425 is an Acti9 Vigi iC60 add-on residual current device (RCD) — a 4-pole, 25 A unit with 30 mA sensitivity, Type A-SI (Super Immunised) earth-leakage protection. It clips onto the outgoing side of an iC60 MCB via the plug-in electrical connection, making it a modular add-on rather than a standalone breaker. The unit snap-mounts onto DIN rail and occupies 6 x 9 mm pitches (54 mm width). Bottom tunnel terminals accept 1…25 mm² rigid or 1…16 mm² flexible conductors; tightening torque is 2 N·m with a 14 mm strip length. The IP20 body (IP40 in modular enclosure) suits enclosed distribution boards — not washdown or outdoor locations. The voltage-independent tripping technology means it operates without an external power supply, relying on the residual current itself to trigger the mechanism. Type A-SI (Super Immunised) provides protection against sinusoidal AC and pulsating DC earth faults, with enhanced immunity to nuisance tripping from high-frequency harmonics or transient surges — relevant on circuits with variable-speed drives, UPS systems, or LED lighting. The instantaneous time delay means no intentional delay before tripping on a fault. Impulse withstand is 8/20 µs, 3000 A per IEC 61009-1.","metaTitle":"Schneider Electric A9Q61425 Vigi iC60 4P 25A 30mA RCD, Obsol","metaDescription":"Schneider Electric A9Q61425 Acti9 Vigi iC60 add-on RCD, 4P, 25A, 30mA, Type A-SI, 400-415VAC. Obsolete — sourced to order against RFQ via independent channels.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"54 mm","Height":"91 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","9 Mm Pitches":"6","Network type":"AC","Product name":"Acti9 Vigi iC60","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Device short name":"Vigi iC60","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"2 N.m bottom","[In] rated current":"25 A","Wire stripping length":"14 mm for bottom connection","Connections - terminals":"Tunnel type terminal downside for 1 cable(s) 1...25 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible with cable end","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Add-on residual current device","Electrical connection to mcb":"Plug in","Earth leakage protection type":"Type A-SI (Super Immunised)","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to IEC 61009-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","Comb busbar and distribution block compatibility":"Bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/edf711ec8d7c4d252650e456c0aa1d65.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9Q61425/addon-residual-current-device-acti9-vigi-ic60-4p-25a-asi-type-instantaneous-30ma-400-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9Q61425/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to A9Q61425?","answer":"No official successor order code is provided in the lifecycle record. A parametric cross-reference to a current Acti9 Vigi iC60 variant (same 4P, 25 A, 30 mA, Type A-SI) should be verified against the specific panel layout and coordination study before substitution."},{"question":"Where can I buy A9Q61425?","answer":"The A9Q61425 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position."},{"question":"What are the key specifications of A9Q61425?","answer":"The A9Q61425 is a 4-pole add-on RCD rated 25 A, 30 mA sensitivity, Type A-SI, for 400…415 V AC 50/60 Hz networks. It mounts on DIN rail, occupies 54 mm width (6 x 9 mm pitches), and uses tunnel terminals for 1…25 mm² conductors."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9Q61425","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9Q61425 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}