{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9R11292","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9R11292","canonicalUrl":"https://aoctrl.com/schneider/A9R11292","factsUrl":"https://aoctrl.com/api/mcp/products/A9R11292","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 RCCB-ID, residual current circuit breaker (RCCB), 2P, 125 A, 30 mA, Type AC, 230 V AC, 50 Hz, grey.","salesMarkdown":"## What this RCCB is and what it guards The Schneider Electric A9R11292 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 range, rated 125 A at 230 V AC, 50 Hz, with 30 mA earth-leakage sensitivity and Type AC protection. 125 A rated current (In) and 230 V operational voltage (Ue) set the load envelope: this RCCB handles the full incoming feed for a sub-distribution board or a high-load outgoer, not just a final subcircuit. The 30 mA sensitivity (IΔn) is the standard for personal protection against indirect contact — it's fast enough to clear before heart fibrillation sets in. The breaking capacity Im is 1250 A at 230 V — that's the maximum prospective fault current the RCCB can interrupt without welding contacts, and it's well above typical domestic fault levels but below what you'd see on a heavy industrial bus. Tunnel-type terminals accept 1.5–50 mm² rigid or 1.5–35 mm² flexible (single cable), or 1.5–16 mm² with two cables per pole. Tightening torque is 3 N·m; strip length 11 mm. IP20 on the body, IP40 inside a modular enclosure — fine for dry indoor distribution boards, not for washdown areas. Certified to IEC/EN 61008-1 and IEC/EN 61008-2-1 (the RCCB product standards). Carries VDE quality label. Ambient storage range -40 to 85 °C.","metaTitle":"Schneider Electric A9R11292 Acti9 RCCB-ID, 125 A, 30 mA, 2P","metaDescription":"Schneider Electric A9R11292 Acti9 RCCB-ID residual current circuit breaker, 125 A, 30 mA sensitivity, Type AC, 2P, 230 V AC, 50 Hz. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"Grey","Height":"86 mm","Standards":"IEC/EN 61008-1 IEC/EN 61008-2-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 RCCB-ID","Mounting mode":"Fixed","Quality labels":"VDE","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"Red/green indicator Trip indicator","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Pollution degree":"3","Device short name":"RCCB-ID","Network frequency":"50 Hz","Poles description":"2P","Tightening torque":"3 N.m","[In] rated current":"125 A","Electrical durability":"2000 cycles","Mechanical durability":"5000 cycles","Wire stripping length":"11 mm","Connections - terminals":"Tunnel type terminals2 cable(s) 1.5...16 mm² flexible Tunnel type terminals2 cable(s) 1.5...16 mm² rigid Tunnel type terminals1 cable(s) 1.5...50 mm² rigid Tunnel type terminals1 cable(s) 1.5...35 mm² flexible Tunnel type terminals1 cable(s) 1.5...35 mm² flexible with ferrule Tunnel type terminals2 cable(s) 1.5...16 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC/EN 60529 IP40 (modular enclosure) conforming to IEC/EN 60529","Provision for padlocking":"Padlockable","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"Yes","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to IEC/EN 61008-1 8/20 µs impulse withstand, 250 A conforming to IEC/EN 61008-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230 V AC 50 Hz conforming to IEC/EN 61008-1 230 V AC 50 Hz conforming to IEC/EN 61008-2-1","Rated breaking and making capacity":"Im = 1250 A 230 V conforming to IEC/EN 61008-1 Im = 1250 A 230 V conforming to IEC/EN 61008-2-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Uimp] rated impulse withstand voltage":"4 kV conforming to IEC/EN 61008-1 4 kV conforming to IEC/EN 61008-2-1","Rated conditional short-circuit current":"Inc 10 kA 125 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$801.11","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/za/en/product/A9R11292/residual-current-circuit-breaker-rccb-acti9-rccbid-2p-125a-ac-type-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9R11292/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9R11292?","answer":"Submit an RFQ through this listing; we confirm pricing and availability at quote time."},{"question":"What is the closest alternative to A9R11292 in the Acti9 family?","answer":"The A9R11292 is a 2P 125 A 30 mA Type AC RCCB. A lower-current sibling (e.g., 63 A or 40 A) would share the same form factor and terminal layout but with a lower In — useful if the load doesn't require the full 125 A rating."},{"question":"What is A9R11292's depth?","answer":"76 mm."},{"question":"What compliance documentation does Schneider provide for A9R11292?","answer":"The device is certified to IEC/EN 61008-1 and IEC/EN 61008-2-1, carries VDE quality label, and is rated for pollution degree 3. RoHS and REACH declarations are standard for the Acti9 range — available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9R11292","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9R11292 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}