{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9R14463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9R14463","canonicalUrl":"https://aoctrl.com/schneider/A9R14463","factsUrl":"https://aoctrl.com/api/mcp/products/A9R14463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iID, A9R14463, residual current circuit breaker (RCCB), 4P, 63 A, 300 mA, Type AC, instantaneous, voltage independent, clip-on DIN rail, white.","salesMarkdown":"The Schneider Electric A9R14463 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 iID range, rated 63 A continuous with 300 mA earth-leakage sensitivity, Type AC, instantaneous trip. The 73.5 mm depth and 72 mm width fit standard modular enclosures; the white housing and left-side neutral position are typical for Acti9 panel layouts. Rated 63 A at 380...415 V AC, 50/60 Hz — sized for the main incoming feed of a small commercial sub-board or the outgoer of a larger distribution panel. The 300 mA sensitivity is a common choice for general-purpose socket-outlet and lighting circuits where a lower 30 mA threshold would cause nuisance tripping on cable leakage. Type AC means it detects sinusoidal alternating earth-leakage currents only; if the load includes rectified or pulsed DC fault currents (e.g., from VFDs, UPS, LED drivers), a Type A or Type B RCCB is required instead. The instantaneous trip (no time delay) ensures fast disconnection on earth faults, but means it cannot be used in selective (S-type) coordination schemes where a delayed downstream RCCB is needed. Voltage-independent tripping technology means the RCCB detects leakage current using the differential transformer alone, without needing a separate supply voltage — it will trip even if the line voltage is lost or severely depressed. This is standard for electromechanical RCCBs and avoids the failure mode of electronic types that may not trip on a lost neutral. ## Installation and wiring constraints Clip-on mounting to a 35 mm DIN rail; the 9 mm pitch count of 8 means it occupies 72 mm (8 modules) of rail width. Terminals accept 1...35 mm² solid or 1...25 mm² flexible (with or without ferrule) — sized for the 63 A incoming cable. The contact position indicator and padlocking provision allow lockout/tagout during maintenance. IP20 on the terminals (finger-safe), IP40 on the modular enclosure — suitable for installation inside a distribution cabinet rated IP4X or better.","metaTitle":"Schneider Electric A9R14463 Acti9 iID RCCB, 63A, 300mA, 4P,","metaDescription":"Schneider Electric A9R14463 Acti9 iID residual current circuit breaker, 63 A rated current, 300 mA sensitivity, 4 poles, Type AC, instantaneous, voltage independent. Sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 61008-1","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iID","Mounting mode":"Clip-on","Surge current":"250 A","lifecycle_stage":"current","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Device short name":"iID","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"63 A","Electrical durability":"AC-1: 15000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"380...415 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 1500 A Im 1500 A","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Uimp] rated impulse withstand voltage":"6 kV","Rated conditional short-circuit current":"10 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9R14463/acti-9-iid-rccb-4p-63a-300ma-type-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9R14463/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9R14463 and how is it quoted for volume purchases?","answer":"The A9R14463 is sourced through independent distribution channels. Submit an RFQ for current pricing and availability; volume commitments can be scheduled against a forecast."},{"question":"What is the closest alternative to A9R14463 in the Acti9 range?","answer":"Within the Acti9 iID family, the main variant difference is sensitivity (30 mA vs 300 mA) and pole count. The A9R14463 is a 4P, 63 A, 300 mA, Type AC, instantaneous unit. A 30 mA version (e.g., A9R14464) would be the direct substitute for circuits requiring personnel protection, but it is not pin-compatible — same footprint, different trip threshold."},{"question":"What compliance documentation does this brand provide for A9R14463?","answer":"The A9R14463 is designed and tested to EN/IEC 61008-1. Standard compliance documentation includes the manufacturer's declaration of conformity (CE), and the product carries the relevant markings for the European market. RoHS and REACH declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9R14463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9R14463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}