{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9R22280","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9R22280","canonicalUrl":"https://aoctrl.com/schneider/A9R22280","factsUrl":"https://aoctrl.com/api/mcp/products/A9R22280","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 2P, 80 A, 100 mA sensitivity, Type A, 230/240 V AC, DIN rail clip-on.","salesMarkdown":"Rated at 80 A with a 100 mA sensitivity, it trips instantaneously when leakage exceeds that threshold, making it suitable for outgoer circuits where a higher threshold is needed to avoid nuisance tripping from normal leakage on longer runs or multiple loads. Rated operational voltage is 230/240 V AC at 50/60 Hz, with an insulation voltage of 500 V AC. Breaking and making capacity is 1500 A (Idm and Im), and the unit withstands 8/20 µs impulse currents up to 250 A per EN/IEC 61008-1. ## Protection class and deployment context The tripping technology is voltage independent, so the device operates without an external power supply, maintaining protection even if the line voltage drops. Mounts via clip-on to a DIN rail, occupying 4 modules of 9 mm pitch (36 mm total width). IP20 rated on the terminals (finger-safe), IP40 within a modular enclosure. The white housing has a toggle control and a contact position indicator.","metaTitle":"Schneider Electric A9R22280 Acti9 iID RCCB, 80 A, 100 mA, 2P","metaDescription":"Schneider Electric A9R22280 Acti9 iID RCCB, 80 A rated current, 100 mA sensitivity, Type A, 2-pole, DIN rail mount. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"69 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"96 mm","Standards":"IEC 61008-2-1 AS/NZS 61008.1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iID","Mounting mode":"Clip-on","Quality labels":"RCM VDE","Embedding depth":"44 mm","lifecycle_stage":"current","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3","Device short name":"iID","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"80 A","Electrical durability":"AC-1: 15000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"100 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"Yes","Locking options description":"Padlocking device","Electromagnetic compatibility":"8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230/240 V AC 50/60 Hz","Rated breaking and making capacity":"Idm 1500 A Im 1500 A","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"6 kV","Rated conditional short-circuit current":"10 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/au/en/product/A9R22280/residual-current-circuit-breaker-rccb-acti9-iid-2p-80a-a-type-100ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9R22280/alternatives.json"},"ai":{"faq":[{"question":"What is the A9R22280 used for?","answer":"The A9R22280 is a residual current circuit breaker (RCCB) used to protect against earth leakage faults in AC electrical installations, typically in distribution boards as an outgoer device. Its 100 mA sensitivity suits circuits with higher natural leakage, such as long cable runs or multiple loads."},{"question":"What are the key ratings of the A9R22280?","answer":"Rated current 80 A, earth-leakage sensitivity 100 mA, Type A (AC and pulsating DC detection), rated operational voltage 230/240 V AC 50/60 Hz, breaking capacity 1500 A, and it mounts on DIN rail occupying 4 modules (36 mm)."},{"question":"Where can I buy the A9R22280?","answer":"The A9R22280 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quotation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9R22280","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9R22280 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}