{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9R46492","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9R46492","canonicalUrl":"https://aoctrl.com/schneider/A9R46492","factsUrl":"https://aoctrl.com/api/mcp/products/A9R46492","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 RCCB-ID, 4P, 125 A, 500 mA, Type B, 400 V AC, IEC/EN 61008-1, A9R46492.","salesMarkdown":"The Schneider Electric A9R46492 is a 4-pole Acti9 RCCB-ID residual current circuit breaker rated at 125 A with a 500 mA earth-leakage sensitivity, Type B, for 400 V AC 50 Hz networks. The instantaneous trip characteristic means it clears earth faults without intentional delay — suited for outgoing circuits where fast disconnection is required. The Type B classification means this RCCB detects AC sinusoidal, pulsating DC, and smooth DC fault currents up to 500 mA — a requirement for circuits with variable-speed drives, UPS systems, or other power-electronics loads that can generate DC leakage. The 125 A rated current and 400 V operational voltage position it for main or sub-main distribution in commercial and industrial panels. The 3 kA impulse withstand (8/20 µs) per IEC/EN 61008-1 gives it reasonable surge immunity for typical installation environments. The tunnel-type terminals accept up to 50 mm² rigid or 35 mm² flexible cable per pole. Tightening torque is 3 N·m, and wire stripping length is 11 mm. The red/green trip indicator gives local status at a glance. IP20 body protection is typical for enclosed distribution boards; the modular enclosure achieves IP40 within the panel.","metaTitle":"Schneider Electric A9R46492 Acti9 RCCB-ID, 4P, 125 A, 500 mA","metaDescription":"Schneider Electric A9R46492 Acti9 RCCB-ID residual current circuit breaker, 4P, 125 A rated current, 500 mA sensitivity, Type B, 400 V AC, IEC/EN 61008-1. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"72 mm","Colour":"Grey","Height":"86 mm","Standards":"IEC/EN 61008-1 IEC/EN 61008-2-1 IEC/EN 62423","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 RCCB-ID","Mounting mode":"Fixed","Quality labels":"VDE","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"Red/green indicator Trip indicator","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Pollution degree":"3","Device short name":"RCCB-ID","Network frequency":"50 Hz","Poles description":"4P","Tightening torque":"3 N.m","[In] rated current":"125 A","Electrical durability":"2000 cycles","Mechanical durability":"5000 cycles","Wire stripping length":"11 mm","Connections - terminals":"Tunnel type terminals2 cable(s) 1.5...16 mm² flexible Tunnel type terminals2 cable(s) 1.5...16 mm² rigid Tunnel type terminals1 cable(s) 1.5...50 mm² rigid Tunnel type terminals1 cable(s) 1.5...35 mm² flexible Tunnel type terminals1 cable(s) 1.5...35 mm² flexible with ferrule Tunnel type terminals2 cable(s) 1.5...16 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC/EN 60529 IP20 conforming to IEC/EN 62423 IP40 (modular enclosure) conforming to IEC/EN 60529 IP40 (modular enclosure) conforming to IEC/EN 62423","Provision for padlocking":"Padlockable","Device location in system":"Outgoer","Earth-leakage sensitivity":"500 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"Yes","Electromagnetic compatibility":"8/20 µs impulse withstand, 3 kA conforming to IEC/EN 61008-1 8/20 µs impulse withstand, 3 kA conforming to IEC/EN 61008-2-1","[Ui] rated insulation voltage":"400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1","Earth-leakage protection class":"Type B","[Ue] rated operational voltage":"400 V AC 50 Hz conforming to IEC/EN 61008-1 400 V AC 50 Hz conforming to IEC/EN 61008-2-1","Rated breaking and making capacity":"Im = 1250 A 400 V conforming to IEC/EN 61008-1 Im = 1250 A 230 V conforming to IEC/EN 61008-2-1","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Uimp] rated impulse withstand voltage":"4 kV conforming to IEC/EN 61008-1 4 kV conforming to IEC/EN 61008-2-1","Rated conditional short-circuit current":"Inc 10 kA 125 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9R46492/residual-current-circuit-breaker-rccb-acti9-rccbid-4p-125a-b-type-500ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9R46492/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to A9R46492 in the Acti9 range?","answer":"Within the Acti9 RCCB-ID family, the closest alternative would be a different sensitivity or pole count variant — for example, a 4P 125 A Type B with 300 mA sensitivity (order code A9R46491). The only spec difference is the earth-leakage sensitivity; form, fit, and function are otherwise identical."},{"question":"Where can I buy A9R46492?","answer":"The A9R46492 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Schneider provide for A9R46492?","answer":"The A9R46492 carries a VDE quality label and is certified to IEC/EN 61008-1, IEC/EN 61008-2-1, and IEC/EN 62423. These standards cover residual current circuit-breaker performance, immunity, and test requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9R46492","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9R46492 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}