{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9S2P100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9S2P100","canonicalUrl":"https://aoctrl.com/schneider/A9S2P100","factsUrl":"https://aoctrl.com/api/mcp/products/A9S2P100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 ISW 40...125, 2P 100A isolator, 2.5 kA breaking capacity, 415 V AC, obsolete.","salesMarkdown":"The A9S2P100 is a 2-pole 100 A isolator from the Schneider Electric Acti9 ISW 40...125 range, designed for isolation duty in distribution boards. It complies with IEC 60669-1 and IEC 60947-3, rated for AC-22 utilisation category — meaning it handles mixed resistive and inductive loads, typical for general distribution isolation. The 2.5 kA rated breaking capacity suits it for downstream isolation where fault levels are moderate. ## Sourcing reality — obsolete part Schneider has marked the A9S2P100 as obsolete. The 2-module 18 mm footprint and 100 A AC-22 rating are the specs to match if evaluating a drop-in from another manufacturer's range. The 100 A rating at 240 V AC is the headline — this isolator handles full panel feed or large subfeed isolation. The 2.5 kA breaking capacity is not a high-fault device; it's intended for isolation, not fault clearing upstream of a breaker. The DC rating is split: 48 V DC for single-pole use, 100 V DC for both poles in series — useful for battery-bank or DC distribution isolation. The 500 V impulse withstand and 6 kV rated insulation voltage give it headroom for 400 V AC systems with typical surge environments.","metaTitle":"A9S2P100 Acti9 ISW 2P 100A Isolator, Obsolete","metaDescription":"A9S2P100 Acti9 ISW 40...125 2P 100A isolator, 2.5 kA breaking capacity, IEC 60947-3. Obsolete — sourced to order against RFQ through independent channels.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Current":"100 A at 240 V AC","Application":"Isolation","Product Status":"Active","Pollution Degree":"3","Breaking Capacity":"2.5 kA","Insulation Voltage Ui":"6 kV","Temp Operating Max":"50 °C","Temp Operating Min":"-20 °C","Utilization Category":"AC-22","Main Product Or Component Type":"Isolator","Ambient Air Temperature Operation":"-20...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9S2P100/acti-9-isolator-xsw-2p-100a-2-5ka-415v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9S2P100/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9S2P100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9S2P100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}