{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TAA2225","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TAA2225","canonicalUrl":"https://aoctrl.com/schneider/A9TAA2225","factsUrl":"https://aoctrl.com/api/mcp/products/A9TAA2225","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Active ARC iC60, arc fault detection add-on block, 25 A, 2P, 230 V AC, clip-on DIN rail, EN/IEC 62606.","salesMarkdown":"The A9TAA2225 is an Acti9 Active ARC iC60 arc fault detection add-on block from Schneider Electric, rated 25 A at 230 V AC on a 50 Hz network. It clips onto the left side of an iC60 MCB (neutral left) and adds series arc-fault detection per EN/IEC 62606, plus overvoltage, earth leakage, and overload event management. The local LED signals ON, OFF, fault trip, and arc fault diagnostics — no need to pull a meter to see what tripped it. The 25 A rated current (In) and 230 V operational voltage (Ue) define the load side: this block monitors the downstream circuit for arc faults and disconnects when it detects one. The 275 V threshold tripping voltage (+/- 5 V) means it catches sustained overvoltage events that could start a fire — not a transient spike, a genuine overvoltage condition. Accuracy on the measurement side is +/- 2 % for voltage and current, +/- 5 % for power, which is tight enough for energy monitoring via the EcoStruxure Panel Server concentrators (Advanced, Entry, or Universal). Electrical durability is 10,000 cycles at 230 V AC per IEC 62606; mechanical durability is 20,000 cycles. That means the arc fault detection electronics and the switching mechanism are rated for the full service life of a typical distribution board — the mechanical cycles outlast the electrical because arc-fault trips are infrequent. Clip-on mounting on DIN rail, 2 module pitches (9 mm each), so it occupies 18 mm of rail width. Terminal capacity is 1...10 mm² flexible or 1...16 mm² rigid, tunnel type, with a 2 N.m tightening torque and 14 mm wire strip length.","metaTitle":"A9TAA2225 Acti9 Active ARC iC60 25A 2P AFDD, 230V","metaDescription":"A9TAA2225 Acti9 Active ARC iC60 arc fault detection device, 25 A, 2P, 230 V AC, EN/IEC 62606. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Width":"54 mm","title":"A9TAA2225","Colour":"White (RAL 9003)","Height":"91 mm","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","Standards":"EN/IEC 62606","description":"Active arc fault detection add-on block, Acti9 Active ARC iC60, 2P, 25A","9 Mm Pitches":"2","Network type":"AC","Product name":"Acti9 Active ARC iC60","Mounting mode":"Clip-on","Quality labels":"NF","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Event management":"Overvoltage Earth leakage Overload","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to IEC 62606","Range of product":"Acti9","Device short name":"ARC iC60","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","[In] rated current":"25 A","Type of measurement":"Voltage Active power Current Power factor","Overvoltage category":"III","Electrical durability":"10000 cycles 230 V AC conforming to IEC 62606","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminal1...10 mm² flexible Tunnel type terminal1...16 mm² rigid","IP degree of protection":"IP20","Device location in system":"Outgoer","Electrical data recording":"Date and time Maintenance indicators","Product or component type":"Active arc fault detection add-on block","Concentrator compatibility":"EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal","Threshold tripping voltage":"275 V for +/- 5 V","Electrical connection to mcb":"By screws","[Ui] rated insulation voltage":"400 V AC 50 Hz","[Ue] rated operational voltage":"230 V AC 50 Hz conforming to IEC 62606","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"4 kV conforming to IEC 62606"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$395.87","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/256f96607b61e452c920fc80eb0383de.pdf","sourceUrl":"https://www.se.com/nl/en/product/A9TAA2225/active-arc-fault-detection-addon-block-acti9-active-arc-ic60-2p-25a/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9TAA2225?","answer":"Submit an RFQ through the distributor. Availability and current pricing are confirmed at quote time; this part is sourced to order through independent distribution."},{"question":"What is A9TAA2225's listed depth (73 mm) on this component line?","answer":"The depth is 73 mm. Combined with a width of 54 mm (2 x 9 mm pitches) and height of 91 mm, it occupies a standard DIN-rail footprint compatible with the Acti9 range."},{"question":"What compliance documentation does this brand provide for A9TAA2225?","answer":"The product carries NF quality label certification and complies with EN/IEC 62606 for arc fault detection devices. Tropicalisation severity B per IEC 60068-2-30 for 28 days is also specified."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TAA2225","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TAA2225 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}