{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TDEC613","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TDEC613","canonicalUrl":"https://aoctrl.com/schneider/A9TDEC613","factsUrl":"https://aoctrl.com/api/mcp/products/A9TDEC613","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Active iCV40N ARC arc-fault detection device, A9TDEC613, 13 A rated current, curve B, 1P+N, 6 kA Icn / 10 kA Icu breaking capacity, clip-on DIN rail mount.","salesMarkdown":"## Arc-fault detection device for final circuits Rated 13 A with a B-curve trip characteristic, it breaks up to 6 kA Icn (IEC 61009-2-1) and 10 kA Icu (IEC 60947-2) at 230 V AC, 50 Hz. The thermal-magnetic trip unit handles overload and short-circuit events; the arc-fault detection circuit monitors for series and parallel arcs, tripping the internal contactor when an arc signature is identified. Local signalling includes ON, OFF, and a fault-trip LED plus an arc-fault diagnostic indicator. The 13 A rated current and B curve mean this device is sized for residential or light-commercial final circuits supplying socket outlets or lighting — B-curve magnetic release (3–5× In) avoids nuisance tripping on inrush from small motors or capacitive loads. The 6 kA Icn service breaking capacity is the standard for domestic distribution boards; the 10 kA Icu ultimate capacity gives headroom for fault currents at the origin of a sub-distribution board. Limitation class 3 means the device limits let-through energy to a low level, aiding downstream coordination. The 1P+N pole arrangement switches the phase and disconnects the neutral, but the neutral is not protected — it is switched only. Neutral position is left. The white (RAL 9003) housing matches standard Acti9 enclosures. Pollution degree 2 per EN/IEC 62606 — suitable for normal indoor environments. Tropicalisation severity B per IEC 60068-2-30 for 28 days covers high-humidity installations (95% RH at 55 °C).","metaTitle":"Schneider Electric A9TDEC613 Acti9 iCV40N ARC, 13 A, Curve B","metaDescription":"Schneider Electric A9TDEC613 Acti9 Active iCV40N ARC arc-fault detection device. 13 A rated current, curve B, 1P+N, 6 kA Icn / 10 kA Icu breaking capacity. Current production. Sour","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White (RAL 9003)","Height":"91 mm","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 60947-2 EN/IEC 61009-2-1","Curve code":"B","Cable Entry":"Top and bottom","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 Active iCV40 ARC","Mounting mode":"Clip-on","Quality labels":"OVE","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Event management":"Overvoltage Earth leakage Overload","Limitation class":"3","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 62606","Breaking capacity":"6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iCV40N ARC","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Operating altitude":"2000 m","Total power losses":"3.255 W","[In] rated current":"13 A","Type of measurement":"Voltage Active power Current Power factor","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles 230 V AC 50 Hz","Mechanical durability":"20000 cycles","Power losses per pole":"2.75 W","Wire stripping length":"14 mm","Breaking capacity code":"N","Connections - terminals":"Tunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Power losses on neutral":"0.507 W","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Number of protected poles":"1","Product or component type":"Active arc fault detection RCBO","Suitability for isolation":"Yes","Concentrator compatibility":"EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal","Contact position indicator":"Yes","Threshold tripping voltage":"275 V for +/- 5 V","Locking options description":"Padlocking device","Product specific application":"Arc fault detection","[Ui] rated insulation voltage":"250 V AC 50 Hz between phase and neutral","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC 50 Hz","Rated breaking and making capacity":"Idm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...80 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...50 °C","[Ics] rated service breaking capacity":"6000 A AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/hk/en/product/A9TDEC613/active-arc-fault-detection-rcbo-acti9-active-icv40n-arc-1p+n-13a-b-curve-30ma-type-asi-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9TDEC613/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9TDEC613 and get a price?","answer":"The A9TDEC613 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9TDEC613?","answer":"The A9TDEC613 has a service breaking capacity (Icn) of 6000 A at 230 V AC 50 Hz per EN/IEC 61009-2-1, and an ultimate breaking capacity (Icu) of 10 kA at 230 V AC 50 Hz per EN/IEC 60947-2."},{"question":"What standards does A9TDEC613 comply with?","answer":"The A9TDEC613 complies with EN/IEC 62606 (arc-fault detection), EN/IEC 61009-1 (RCBO), EN/IEC 60947-2 (MCB), and EN/IEC 61009-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TDEC613","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TDEC613 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}