{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TDF3610","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TDF3610","canonicalUrl":"https://aoctrl.com/schneider/A9TDF3610","factsUrl":"https://aoctrl.com/api/mcp/products/A9TDF3610","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iCV40N ARC, 1P+N, 10 A, C-curve, 6 kA Icn / 10 kA Icu, arc fault detection device (AFDD) + MCB combination, DIN-rail mount.","salesMarkdown":"## Arc-fault + overcurrent in one 36 mm module The A9TDF3610 is a Schneider Electric Acti9 iCV40N ARC — a combined arc-fault detection device (AFDD) and miniature circuit breaker in a single 1P+N, 36 mm wide DIN-rail module. It carries a 10 A rated current with a C-curve magnetic trip (5–10 x In) and a 6 kA Icn / 10 kA Icu breaking capacity at 230 V AC, 50 Hz, per EN/IEC 61009-2-1 and EN/IEC 60947-2. The arc-fault detection is the primary differentiator here: it monitors for the high-frequency signature of a series or parallel arc (e.g., a loose terminal, a crushed cable) and trips before the arc has time to propagate into a panel fire. The diagnostic LED on the toggle gives a local indication of an arc-fault trip versus an overload or short — saves the commissioning engineer a clamp-meter hunt on a nuisance-trip callout. ## What the 6 kA Icn / 10 kA Icu means for your panel The 6 kA Icn (rated short-circuit capacity per EN/IEC 61009-2-1) is the breaker's tested interrupting rating under the MCB standard — it clears a 6 kA fault at 230 V and remains serviceable afterward. The 10 kA Icu (ultimate breaking capacity per EN/IEC 60947-2) is the higher one-shot rating under the industrial standard; the breaker will interrupt a 10 kA fault but may need replacement afterward. For most commercial and light-industrial distribution boards with a prospective fault current under 6 kA, the Icn figure governs the daily duty. The 10 kA Icu gives headroom for a stronger upstream transformer or a closer fault location without cascading. The C-curve (5–10 x In) means the magnetic trip fires between 50 A and 100 A — suitable for general-purpose loads with moderate inrush, like lighting banks, small motor circuits, or socket outlets. The thermal-magnetic trip mechanism is a traditional bimetal + solenoid, field-reliable and predictable. Cable entry from top or bottom — no forced feed direction, which helps with busbar or loop-through wiring in a crowded enclosure. Pollution degree 2 (non-conductive dust, occasional condensation) per EN/IEC 62606.","metaTitle":"A9TDF3610 Acti9 iCV40N ARC 10A C-Curve AFDD+MCB, 6kA","metaDescription":"A9TDF3610 Acti9 iCV40N ARC 10A, C-curve, 6kA Icn/10kA Icu breaking capacity. Arc fault detection per EN/IEC 62606. Current lifecycle stage. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White (RAL 9003)","Height":"91 mm","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 60947-2 EN/IEC 61009-2-1","Curve code":"C","Cable Entry":"Top and bottom","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iCV40 ARC","Mounting mode":"Clip-on","Quality labels":"IMQ AENOR OVE","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Limitation class":"3","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 62606","Breaking capacity":"6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iCV40N ARC","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Operating altitude":"2000 m","Total power losses":"2.906 W","[In] rated current":"10 A","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles 230 V AC 50 Hz","Mechanical durability":"20000 cycles","Power losses per pole":"2.55 W","Wire stripping length":"14 mm","Breaking capacity code":"N","Connections - terminals":"Tunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Power losses on neutral":"0.355 W","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Number of protected poles":"1","Product or component type":"Arc fault detection RCBO","Suitability for isolation":"Yes","Contact position indicator":"Yes","Threshold tripping voltage":"275 V for +/- 5 V","Locking options description":"Padlocking device","Product specific application":"Arc fault detection","[Ui] rated insulation voltage":"250 V AC 50 Hz between phase and neutral","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC 50 Hz","Rated breaking and making capacity":"Idm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...80 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...50 °C","[Ics] rated service breaking capacity":"6000 A AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$323.68","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9TDF3610/arc-fault-detection-rcbo-acti9-icv40n-arc-1p+n-10a-c-curve-30ma-type-asi-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9TDF3610/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9TDF3610 and how is it quoted for volume purchases?","answer":"The A9TDF3610 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What is A9TDF3610's listed depth (73 mm) on this component line?","answer":"The A9TDF3610 has a depth of 73 mm, a width of 36 mm (4 x 9 mm pitches), and a height of 91 mm — standard modular dimensions for a 1P+N DIN-rail device."},{"question":"What compliance documentation does this brand provide for A9TDF3610 (RoHS, REACH, UL, IEC)?","answer":"The A9TDF3610 is certified to EN/IEC 62606 (arc-fault detection), EN/IEC 61009-1, EN/IEC 60947-2, and EN/IEC 61009-2-1. It carries IMQ, AENOR, and OVE quality labels. RoHS/REACH declarations are standard for the Acti9 range and available on request."},{"question":"What is A9TDF3610's listed range (Acti9) on this component line?","answer":"The A9TDF3610 belongs to the Schneider Electric Acti9 range, specifically the iCV40N ARC series — a combined AFDD + MCB in a 1P+N form factor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TDF3610","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TDF3610 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}