{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TDFC632","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TDFC632","canonicalUrl":"https://aoctrl.com/schneider/A9TDFC632","factsUrl":"https://aoctrl.com/api/mcp/products/A9TDFC632","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Active iCV40N ARC RCBO, A9TDFC632, 32 A rated, C-curve, 1P+N, 6 kA Icn / 10 kA Icu breaking capacity, DIN rail clip-on, white (RAL 9003).","salesMarkdown":"The Schneider Electric A9TDFC632 is an Acti9 Active iCV40N ARC RCBO — a combined residual current device with overcurrent protection, rated 32 A with a C-curve trip characteristic, 1P+N poles, and a 6 kA Icn / 10 kA Icu breaking capacity at 230 V AC. The 'ARC' designation means it includes arc-fault detection, not just earth-leakage and overload — it watches for the high-frequency signature of a series or parallel arc and trips before the arc can start a fire. The 32 A C-curve is the standard choice for general-purpose socket-outlet circuits and small inductive loads — the magnetic trip threshold sits at 5 to 10 times In (160–320 A), so it won't nuisance-trip on motor inrush or capacitor charging. The 6 kA Icn is the service breaking capacity per EN/IEC 61009-2-1; the 10 kA Icu per EN/IEC 60947-2 is the ultimate breaking capacity, meaning the device can safely interrupt a 10 kA fault once and still hold its insulation. For a domestic or light commercial distribution board with a typical upstream fault level under 6 kA, the N breaking-capacity code is adequate. The thermal-magnetic trip unit uses a bimetal for overload and a solenoid for short-circuit — no electronics in the trip path, so it's immune to supply-voltage dips. The arc-fault detection (AFDD function) complies with EN/IEC 62606. It measures both the current waveform and the high-frequency noise that a loose connection or damaged cable generates. The local signalling includes a dedicated LED for arc-fault diagnostic — useful when a nuisance trip happens and you need to know whether it was a real arc or a false positive from a brush motor. The device also handles overvoltage, earth leakage, and overload events, with a toggle for manual on/off and fault reset. Accuracy for the measurement functions is stated as voltage ±2%, current ±2%, and power ±5%. That's fine for load monitoring and energy allocation; not metering-grade, but enough to tell you which circuit is drawing what. The tropicalisation rating (severity B per IEC 60068-2-30 for 28 days) means it survives hot, humid environments without internal condensation damage — relevant for enclosures in laundries, greenhouses, or coastal plant rooms. Pollution degree 2 (non-conductive dust, occasional condensation) and overvoltage category III (distribution-board level) define its installation environment.","metaTitle":"A9TDFC632 Acti9 iCV40N ARC 32A C-curve 1P+N RCBO","metaDescription":"Schneider Electric A9TDFC632 Acti9 Active iCV40N ARC RCBO, 32A, C-curve, 1P+N, 6kA Icn, 10kA Icu, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White (RAL 9003)","Height":"91 mm","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 60947-2 EN/IEC 61009-2-1","Curve code":"C","Cable Entry":"Top and bottom","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 Active iCV40 ARC","Mounting mode":"Clip-on","Quality labels":"AENOR","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Event management":"Overvoltage Earth leakage Overload","Limitation class":"3","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 62606","Breaking capacity":"6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"iCV40N ARC","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Operating altitude":"2000 m","Total power losses":"6.333 W","[In] rated current":"32 A","Type of measurement":"Voltage Active power Current Power factor","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles 230 V AC 50 Hz","Mechanical durability":"20000 cycles","Power losses per pole":"4.48 W","Wire stripping length":"14 mm","Breaking capacity code":"N","Connections - terminals":"Tunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Power losses on neutral":"1.852 W","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Number of protected poles":"1","Product or component type":"Active arc fault detection RCBO","Suitability for isolation":"Yes","Concentrator compatibility":"EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal","Contact position indicator":"Yes","Threshold tripping voltage":"275 V for +/- 5 V","Locking options description":"Padlocking device","Product specific application":"Arc fault detection","[Ui] rated insulation voltage":"250 V AC 50 Hz between phase and neutral","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC 50 Hz","Rated breaking and making capacity":"Idm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...80 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...50 °C","[Ics] rated service breaking capacity":"6000 A AC 50 Hz conforming to EN/IEC 61009-2-1 5 kA AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$359.91","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/A9TDFC632/active-arc-fault-detection-rcbo-acti9-active-icv40n-arc-1p+n-32a-c-curve-30ma-type-asi-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9TDFC632/alternatives.json"},"ai":{"faq":[{"question":"What is the A9TDFC632's rated current and breaking capacity?","answer":"Rated current is 32 A with a C-curve. Breaking capacity is 6 kA Icn at 230 V AC per EN/IEC 61009-2-1 and 10 kA Icu at 230 V AC per EN/IEC 60947-2."},{"question":"What standards does the A9TDFC632 comply with?","answer":"It complies with EN/IEC 62606 (arc-fault detection), EN/IEC 61009-1 (RCBO general), EN/IEC 60947-2 (circuit-breaker), and EN/IEC 61009-2-1 (RCBO functional). It also carries an AENOR quality label."},{"question":"Where can I buy the A9TDFC632 and how is it quoted?","answer":"The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What does the 'ARC' in the product name mean?","answer":"The 'ARC' designation means the device includes arc-fault detection (AFDD) per EN/IEC 62606, in addition to overcurrent and earth-leakage protection. It monitors for the high-frequency signature of a series or parallel arc and trips to prevent fire."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TDFC632","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TDFC632 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}