{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TDNC610","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TDNC610","canonicalUrl":"https://aoctrl.com/schneider/A9TDNC610","factsUrl":"https://aoctrl.com/api/mcp/products/A9TDNC610","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Active iCV40N ARC, A9TDNC610, RCBO, 1P+N, 10 A, curve C, 6 kA Icn at 230 V AC, DIN rail clip-on.","salesMarkdown":"It combines earth leakage and overload/arc-fault detection in a single 36 mm wide module that clips onto a DIN rail. The arc-fault detection (the 'ARC' in the name) is the main differentiator here. It monitors the waveform for the high-frequency signature of a series or parallel arc — loose connection, damaged cable, carbonised insulation — and trips before the fault escalates. That's a layer of protection a standard RCBO or MCB alone doesn't cover. Breaking capacity of 6000 A Icn at 230 V AC meets the EN/IEC 61009-2-1 standard for RCBOs. The thermal-magnetic trip unit gives the C-curve response: magnetic trip between 5 and 10 times In (50–100 A for this 10 A unit), thermal overload following the inverse-time characteristic. Accuracy specs on the metering side: voltage ±2 %, current ±2 %, power ±5 %. That's not revenue-grade, but it's good enough for energy monitoring and fault logging — you'll see a 2 % drift on a 230 V reading before the protection elements act. Mechanical durability matches at 20000 cycles. For a panel that sees daily switching, that's roughly a 10-year service life at 5 operations per day. Clip-on mounting to a DIN rail, 36 mm width (2 module pitches at 18 mm each, though the evidence lists 4 pitches of 9 mm). Height 91 mm, depth 73 mm — fits standard distribution board cutouts. Neutral on the left, cable entry from top and bottom. The spring-cage or screw terminal (toggle control) accepts solid or stranded copper up to the rated cross-section. Pollution degree 2 — suitable for normal industrial or commercial environments where only non-conductive pollution occurs, with occasional condensation. Tropicalisation severity B per IEC 60068-2-30 for 28 days — the device is tested for damp-heat cyclic exposure. Compliance documentation: the device carries approvals to EN/IEC 62606 (arc-fault detection device standard), EN/IEC 61009-1, and EN/IEC 61009-2-1 (RCBO standards). Targeted country is India, but the standards are international.","metaTitle":"Schneider Electric A9TDNC610 Acti9 iCV40N ARC, 10 A, Curve C","metaDescription":"Schneider Electric A9TDNC610 Acti9 Active iCV40N ARC RCBO. 10 A rated, curve C, 6 kA breaking capacity at 230 V AC. 1P+N, DIN rail mount. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White (RAL 9003)","Height":"91 mm","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","Cable Entry":"Top and bottom","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 Active iCV40 ARC","Mounting mode":"Clip-on","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Event management":"Earth leakage Overload","Limitation class":"3","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 62606","Targeted country":"India","Breaking capacity":"6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40N ARC","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Operating altitude":"2000 m","Total power losses":"2.906 W","[In] rated current":"10 A","Type of measurement":"Voltage Active power Current Power factor","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles 230 V AC 50 Hz","Mechanical durability":"20000 cycles","Power losses per pole":"2.55 W","Wire stripping length":"14 mm","Breaking capacity code":"N","Connections - terminals":"Tunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Power losses on neutral":"0.355 W","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Number of protected poles":"1","Product or component type":"Active arc fault detection RCBO","Suitability for isolation":"Yes","Concentrator compatibility":"EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal","Contact position indicator":"Yes","Threshold tripping voltage":"275 V for +/- 5 V","Locking options description":"Padlocking device","Product specific application":"Arc fault detection","[Ui] rated insulation voltage":"250 V AC 50 Hz between phase and neutral","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC 50 Hz","Rated breaking and making capacity":"Idm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...80 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...50 °C","[Ics] rated service breaking capacity":"6000 A AC 50 Hz conforming to IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9TDNC610/active-arc-fault-detection-rcbo-acti9-active-icv40n-arc-1p+n-10a-c-curve-30ma-type-asi-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9TDNC610/alternatives.json"},"ai":{"faq":[{"question":"What compliance standards does the A9TDNC610 meet?","answer":"It complies with EN/IEC 62606 (arc-fault detection), EN/IEC 61009-1, and EN/IEC 61009-2-1 (RCBO standards). It is rated overvoltage category III and pollution degree 2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TDNC610","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TDNC610 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}