{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TDNC616","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TDNC616","canonicalUrl":"https://aoctrl.com/schneider/A9TDNC616","factsUrl":"https://aoctrl.com/api/mcp/products/A9TDNC616","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Active iCV40N ARC RCBO, 1P+N, 16 A, C-curve, 6 kA Icn at 230 V AC, DIN-rail clip-on, white (RAL 9003).","salesMarkdown":"The Schneider Electric A9TDNC616 is an Acti9 Active iCV40N ARC residual current circuit breaker with integral overcurrent protection (RCBO) in a 1P+N format, rated at 16 A with a C-curve trip characteristic. The breaking capacity is 6000 A Icn at 230 V AC 50 Hz, certified to EN/IEC 61009-2-1, which covers the majority of domestic and commercial fault-level requirements in 230 V networks. This unit also carries arc-fault detection (AFDD) per EN/IEC 62606, adding series and parallel arc-fault protection on top of the thermal-magnetic and residual-current elements. The local signalling includes a fault-trip LED and an arc-fault diagnostic indicator, which helps a field technician identify the cause of a trip without additional test gear. The part is listed with a targeted country of India, but the EN/IEC certifications (EN/IEC 62606, EN/IEC 61009-1, EN/IEC 61009-2-1) make it acceptable in any jurisdiction that recognises those standards. For UL-listed installations, verify local acceptance of the IEC marking. Cable entry from top or bottom, with a wire stripping length of 14 mm and a tightening torque of 2 N·m. Tropicalisation severity B per IEC 60068-2-30 for 28 days is standard, so the unit holds up in high-humidity environments (95 % RH at 55 °C). ## Electrical performance and metering Built-in measurement of voltage, current, active power, and power factor with stated accuracies of ±2 % for voltage and current, ±5 % for power. This allows the RCBO to double as a basic energy-monitoring point in the distribution board without a separate meter. Total power losses are 3.408 W (2.65 W per pole). Electrical durability is 20,000 cycles at 230 V AC 50 Hz, matching the mechanical durability of 20,000 cycles. Limitation class 3 means the device limits let-through energy well in a fault event.","metaTitle":"Schneider A9TDNC616 Acti9 iCV40N ARC, 16 A, 6 kA, C-curve","metaDescription":"Schneider Electric A9TDNC616 Acti9 Active iCV40N ARC RCBO. 16 A rated, 6 kA breaking capacity at 230 V AC, C-curve, 1P+N. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White (RAL 9003)","Height":"91 mm","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","Cable Entry":"Top and bottom","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 Active iCV40 ARC","Mounting mode":"Clip-on","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Event management":"Earth leakage Overload","Limitation class":"3","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 62606","Targeted country":"India","Breaking capacity":"6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40N ARC","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Operating altitude":"2000 m","Total power losses":"3.408 W","[In] rated current":"16 A","Type of measurement":"Voltage Active power Current Power factor","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles 230 V AC 50 Hz","Mechanical durability":"20000 cycles","Power losses per pole":"2.65 W","Wire stripping length":"14 mm","Breaking capacity code":"N","Connections - terminals":"Tunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Power losses on neutral":"0.763 W","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Number of protected poles":"1","Product or component type":"Active arc fault detection RCBO","Suitability for isolation":"Yes","Concentrator compatibility":"EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal","Contact position indicator":"Yes","Threshold tripping voltage":"275 V for +/- 5 V","Locking options description":"Padlocking device","Product specific application":"Arc fault detection","[Ui] rated insulation voltage":"250 V AC 50 Hz between phase and neutral","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC 50 Hz","Rated breaking and making capacity":"Idm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...80 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...50 °C","[Ics] rated service breaking capacity":"6000 A AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9TDNC616/active-arc-fault-detection-rcbo-acti9-active-icv40n-arc-1p+n-16a-c-curve-30ma-type-asi-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9TDNC616/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9TDNC616 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing."},{"question":"What is A9TDNC616's breaking capacity?","answer":"6000 A Icn at 230 V AC 50 Hz, certified to EN/IEC 61009-2-1."},{"question":"What standards does A9TDNC616 comply with?","answer":"It complies with EN/IEC 62606 (arc-fault detection), EN/IEC 61009-1, and EN/IEC 61009-2-1 (RCBO)."},{"question":"What is the width of A9TDNC616?","answer":"36 mm (2 modules at 9 mm pitch), clip-on DIN-rail mount."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TDNC616","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TDNC616 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}