{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9TDNC625","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9TDNC625","canonicalUrl":"https://aoctrl.com/schneider/A9TDNC625","factsUrl":"https://aoctrl.com/api/mcp/products/A9TDNC625","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Active iCV40N ARC RCBO, order code A9TDNC625, 1P+N, 25 A rated current, curve C, 6 kA breaking capacity, DIN rail mount.","salesMarkdown":"The Schneider Electric A9TDNC625 is an Acti9 Active iCV40N ARC residual-current circuit breaker with overcurrent protection (RCBO) in a 1P+N pole configuration, rated 25 A with a C trip curve. The thermal-magnetic trip unit handles both overload and short-circuit protection, while the earth leakage and arc-fault detection (event management: earth leakage, overload) are integrated — the local signalling includes ON, OFF, fault trip LED, and arc fault diagnostic. This is a current-production part (lifecycle stage: current). The 1P+N configuration switches the phase and provides a switched neutral; neutral position is left, so it fits standard single-phase distribution boards where the neutral bus is on the left. The 73 mm depth and 91 mm height are standard for Acti9 RCBOs, so it fits existing Acti9 enclosures without crowding. ## Deployment context The RCBO is tropicalised to severity B per IEC 60068-2-30 for 28 days, so it handles high-humidity environments (95 % RH at 55 °C) without condensation issues. Pollution degree 2 (non-conductive pollution, occasional condensation) covers typical clean indoor installations. Operating altitude is 2000 m — no derating needed for most sites.","metaTitle":"Schneider Electric A9TDNC625 Acti9 iCV40N ARC, 25 A, 1P+N RC","metaDescription":"Schneider Electric A9TDNC625 Acti9 Active iCV40N ARC RCBO, 25 A rated current, 6 kA breaking capacity, 1P+N, curve C, DIN rail mount, active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"36 mm","Colour":"White (RAL 9003)","Height":"91 mm","Accuracy":"Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %","Standards":"EN/IEC 62606 EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","Cable Entry":"Top and bottom","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 Active iCV40 ARC","Mounting mode":"Clip-on","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Event management":"Earth leakage Overload","Limitation class":"3","Local signalling":"ON, OFF, fault trip LED arc fault diagnostic","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 62606","Targeted country":"India","Breaking capacity":"6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Device short name":"iCV40N ARC","Network frequency":"50 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Operating altitude":"2000 m","Total power losses":"5.487 W","[In] rated current":"25 A","Type of measurement":"Voltage Active power Current Power factor","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles 230 V AC 50 Hz","Mechanical durability":"20000 cycles","Power losses per pole":"3.5 W","Wire stripping length":"14 mm","Breaking capacity code":"N","Connections - terminals":"Tunnel type terminal 1...16 mm² rigid Tunnel type terminal 1...10 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Power losses on neutral":"1.991 W","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Electrical data recording":"Date and time Maintenance indicators","Number of protected poles":"1","Product or component type":"Active arc fault detection RCBO","Suitability for isolation":"Yes","Concentrator compatibility":"EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal","Contact position indicator":"Yes","Threshold tripping voltage":"275 V for +/- 5 V","Locking options description":"Padlocking device","Product specific application":"Arc fault detection","[Ui] rated insulation voltage":"250 V AC 50 Hz between phase and neutral","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"230 V AC 50 Hz","Rated breaking and making capacity":"Idm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1","Ambient air temperature for storage":"-40...80 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...50 °C","[Ics] rated service breaking capacity":"6000 A AC 50 Hz conforming to EN/IEC 61009-2-1","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9TDNC625/active-arc-fault-detection-rcbo-acti9-active-icv40n-arc-1p+n-25a-c-curve-30ma-type-asi-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9TDNC625/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9TDNC625 and how do I get a price?","answer":"The A9TDNC625 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is A9TDNC625's listed depth (73 mm) on this component line?","answer":"The depth is 73 mm."},{"question":"What is A9TDNC625's listed range (Acti9) on this component line?","answer":"The range is Acti9."},{"question":"What compliance documentation does this brand provide for A9TDNC625 (RoHS, REACH, UL, IEC)?","answer":"The A9TDNC625 is certified to EN/IEC 62606, EN/IEC 61009-1, and EN/IEC 61009-2-1. The evidence does not list RoHS, REACH, or UL specifically, but the IEC standards cover the core safety and performance requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9TDNC625","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9TDNC625 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}